6.3.3 Bearings
The bearings are either rolling, ball or roller, depending on the size of the electro-mechanical unit, and are all sized to last for 50,000 hours of
operation under normal conditions.
6.3.4 Mechanical seals
The estimated duration of safe operation for the mechanical seals is 20,000 hours under normal conditions and 7,000 hours in faulty operating
conditions (dry operation or with fluids containing debris), at which point they need to be changed.
7. TROUBLESHOOTING GUIDE
DEFECTS
POSSIBLE CAUSE
SOLUTION
Motor does not run
no power
check power supply line
incorrect power supply voltage
set voltage at level stated on nameplate
incorrect starting type
check starting type
circuit breaker and/or fuses tripped
check calibration of circuit breaker and/or that the
correct type of fuses are fitted
impeller jammed
identify the cause of the jam and remove it
thermal protection tripped
wait for motor to cool
The pump works but little or no liquid is
delivered
check valve jammed
clean valve and check its operation
pipeline obstructed
find and remove the obstruction
impeller, valve or pipelines obstructed
find and remove the obstruction
liquid level too low
stop the pump at once and install a level control
system
wrong rotation direction
swap phases
Thermal protection tripped
impeller jammed
identify the cause of the jam and remove it
EN
Summary of Contents for UNIQA M08L
Page 62: ...62 2 2 1 Zenit 2 2 IP44 4 69 1 2 3 2 3 5 69 2 4 20 C 60 C 30 13 C 2 3 3 1 EX 6 69 RU...
Page 67: ...67 6 6 1 Zenit UNIQA EX Zenit Zenit Zenit 6 2 6 3 ATEX Zenit 4 3 5 5 1 3 2 5 2 5 3 70 RU...
Page 68: ...68 6 3 1 Zenit Zenit 6 3 2 6 3 3 50000 6 3 4 20000 7000 7 RU...
Page 78: ...78 Notes...
Page 79: ......
Page 80: ...zenit com 27270100901800200 Rev 7 10 02 17 water solutions...