background image

56

AH1500-001_v01

AUTOMATIC STEAM SHUT-OFF 

The humidifier has an automatic steam off function, which 

will be activated in the following cases:

a) 

If  during  operation  of  appliance  the  water  level  drops 

below  the  required  level,  a  safety  switch  automatically 

stops  the  appliance  operation,  preventing  it  from 

overheating. At the same time you will hear a triple beep, 

the operation indicators on buttons will flash, reminding 

of the need to fill the water tank.

  

  In  the  sleep  mode,  only  the  symbol  „ ”  is 

blinking on the LCD.

If  within  one  minute,  the  water  tank  is  not  filled,  the  air 

humidifier automatically turns off.

  

  If  at  the  time  of  filling  the  water  tank  the 

appliance  will  automatically  switch  off,  after 

installing  the  water  tank  on  the  humidifier’s 

base, press the “ON/OFF” button to restart the 

appliance.

b) 

During  operation,  removing  the  water  tank  or  incorrect 

installation  of  the  tank  on  the  base  of  air  humidifier 

will  launch  a  safety  switch  that  automatically  stops 

the  appliance,  preventing  it  from  overheating.  If  within 

15  seconds  the  water  tank  will  not  be  placed  on  the 

humidifier’s  base,  you  will  hear  three  beeps  and  the 

indicators on the buttons will flash.

  

  In  the  sleep  mode,  only  the  symbol  „ ”  is 

blinking on the LCD.

After  placing  the  water  tank  on  the  humidifier’s  base,  the 

appliance  within  3  seconds  will  return  to  normal  operation 

mode. However, if within one minute the water tank will not be 

placed on the humidifier’s base, the appliance automatically 

turns off.

  

  If  the  appliance  was  automatically  switched 

off  after  installing  the  water  tank  on  the 

humidifier’s base, press the “ON/OFF” button 

to restart the appliance.

DRAINING THE BASE OF HUMIDIFIER

1

 Turn the appliance off by pressing the “ON/OFF” button 

and unplug the power cord from the wall outlet.

2

 Remove the water tank from the base of the humidifier, 

lifting it up with the handle.

3

 Empty  the  base  of  the  humidifier  removing  the 

accumulated water (as shown in the photo).

 

  Pouring water out in the wrong way may result 

in  water  entering  the  outlet  of  the  fan  and 

consequently  cause  serious  damage  to  the 

humidifier.

 

  If  water  gets  into  the  fan  outlet,  contact  your 

service center.

E

Between 60-85% RH - the amount of generated steam 

 

is being reduced, on the “MODES” button one operation 

indicator shall fade,

Above 85% RH - production of steam shall be ceased , 

 

the display shows “H% RH”. When the level of humidity 

in the room drops to 60% RH, the appliance shall resume 

production of steam.

The  “MODES”  button

  is  used  to  manually  select  the 

operation  mode.  When  the  appliance  is  started,  pressing 

a single button will switch from automatic mode to manual 

mode, while reducing the amount of generated steam (the 

operation indicator on the “AUTO” button and one segment 

of the indicator on the “MODES” button shall fade). Pressing 

the button again starts the function of sleep and shall reduce 

the  amount  of  generated  steam  (the  second  segment  of 

indicator on the “MODES” button will fade and the display 

will show the symbol „ ”).

  

  During  the  sleep  function  you  cannot  control 

the amount of generated steam. Pressing any 

button  (except  the  “ON/OFF”)  will  disable  the 

sleep  function  and  increase  the  amount  of 

generated steam.

Pressing the “MODES” button shall turn off the sleep function 

and increase the amount of generated steam (both segments 

of the operation indicator on the “MODES” button will be lit).

The “ION” button

 is used to activate the ionization. The air 

humidifier has a built-in generator which produces negative 

ions that improve air quality and help to improve your health. 

After pressing the “ION” button, the appliance will produce 

negative ions, the operation indicator on the button will light 

up. At any time you can turn this function off, by pressing 

again the “ION” button.

  

  The  function  of  ionization  does  not  work  in 

sleep mode.

The  “AUTO”  button 

lets  you  switch  from  manual  to 

automatic mode, by pressing the button, operation indicator 

on the button will light up. To disable the automatic mode, 

press the “MODES” button.

STARTING THE APPLIANCE

1

 Connect the power cord into an electrical outlet.

  

  The  display  and  operation  indicators  on  the 

buttons  will  turn  to  illuminate  to  indicate  the 

appliance is connected to the supply mains.

2

 Press  “ON/OFF”  button.  You  will  hear  the  “tune”,  air 

humidifier will run in automatic mode. Operation indicators 

on  the  button  “ON/OFF”,  “AUTO”  and  “MODES”  will  flash 

and the display shows the level of humidity in the room.

 

  Do not operate the appliance if the water tank 

is empty.

3

 To turn the appliance off, press the “ON / OFF” button. The 

display and operation indicators on the buttons will be off.

C

Summary of Contents for AH1500

Page 1: ...bjem n doby na vodu 3 6 L 3 N zk rove hlu nosti za zen 30 dB 4 Mo nost nep etr it ho provozu po dobu 13 h 1 V kon zariadenia 30 W 2 Ve k objem n doby na vodu 3 6 L 3 N zka rove hlasitosti zariadenia 3...

Page 2: ...w miejscach gdzie panuje wysoka temperatura w pobli u komputer w lub czu ego sprz tu elektronicznego Je eli z urz dzenia wydobywa si nieprzyjemny zapach lub urz dzenie emituje dziwne d wi ki wy cz je...

Page 3: ...zbiornik na wod nak adaj c go na podstaw nawil acza Woda zacznie prze lewa si do podstawy nawil acza Za dysz pary wodnej na zbiornik na wod B nie usterek W przypadku powtarzania si problemu zwr si do...

Page 4: ...D i przyciskami s u cymi do uruchamia nia urz dzenia i jego obs ugi Ka dy przycisk wyposa ony jest we wska nik dzia ania Pod wietlony wska nik informuje o dzia aniu urz dzenia i uruchomionym trybie pr...

Page 5: ...by nie pozostawi p ynu czyszcz cego p ynu do mycia naczy w zbior niku na wod 5 Opr nij podstaw nawil acza z nagromadzonej wody patrz punkt OPR NIANIE PODSTAWY NAWIL ACZA E D 6 Przetwornik ultrad wi ko...

Page 6: ...L ACZA 4 Podstaw nawil acza odwr tak by strona z panelem sterowania le a a na pod o u 5 Naci nij zaczep w pokrywie filtra i wyci gnij filtr wlotowy z podstawy nawil acza powietrza Filtr przep ucz pod...

Page 7: ...powierzchni Mgie ka wydobywa si dooko a dyszy Szczelina pomi dzy dysz a zasobnikiem Zamocz na chwilk dysz w wodzie nast p nie zamontuj j w urz dzeniu Ekologia Zadbajmy o rodowisko Ka dy u ytkownik mo...

Page 8: ...jte do n doby na vodu l ky terick oleje ani dn jin chemick l tky Pou vejte vychlazenou a p eva enou nebo destilova nou vodu Teplota vody nesm p es hnout 40 C Nevystavujte p stroj p m mu p soben slune...

Page 9: ...eno pro spou t n p stroje Po jeho stisknut se rozezn zvukov sign l a zvlh o va se zapne v automatick m re imu Ukazatel na tla t c ch se podsv t a na displeji bude zobrazena rove vlhkosti v m stnosti...

Page 10: ...60 RH zvlh ova vytv v t mno stv p ry 60 85 RH doch z k zmen en mno stv vytv en p ry na tla tku MODES zhasne jeden ukazatel pr ce v t ne 85 RH doch z k zastaven vytv en p ry na displeji je zobrazeno H...

Page 11: ...an roztok nalijte do podstavce zvlh ova e na 30 minut 3 Vypr zdn te podstavec zvlh ova e viz bod VYPR ZD N N PODSTAVCE ZVLH OVA E a m kk m had kem odstra te vodn k men D 4 Opl chn te podstavec zvlh ov...

Page 12: ...v n plov kov ho vyp na e Vyjm te z sobn k vody ze z kladny a odblo kujte plov kov vyp na Pokud bude rove vlhkosti v m stnosti v t ne 85 RH dojde k zastaven vytv en p ry na displeji bude zobrazeno H RH...

Page 13: ...obecn spr vy o recykla n m st edisku ke kter mu p slu te Toto elektroza zen nepat do komun ln ho odpadu Spo t ebitel p isp v na ekologickou likvidaci v robku ZELMER CENTRAL EUROPE s r o je zapojena do...

Page 14: ...lieky terick oleje ani iadne in chemick prostriedky Pou vajte vychladnut prevaren vodu alebo destilo van vodu Teplota vody nesmie by vy ia ne 40 C Nevystavujte pr stroj priamemu p sobeniu slne n ch l...

Page 15: ...stroja a zvolenom pracov nom re ime Ka d stla enie tla idla sprev dza zvukov sign l Tla idlo zapni vypni ON OFF sl i na zapnutie pr stroja Po stla en tla idla zapni vypni ON OFF budete po u hudbu Zvlh...

Page 16: ...osti v miestnosti Zvlh ova vzduchu v z vislosti od zobrazovanej hodnoty prisp sobuje mno stvo vytv ranej pary Ak rove vlhkosti v miestnosti je menej ne 60 RH zvlh ova vytv ra v ie mno stvo pary medzi...

Page 17: ...vlh ova a vytrite ich a vysu te Pr stroje je najlep ie skladova v origin lnom obale D ODKAME OVANIE ZVLH OVA A VZDUCHU 1 Vypnite pr stroj Stla te tla idlo ON OFF a odpojte nap jac elektrick k bel zo z...

Page 18: ...a do elektrickej z suvky V pr stroji nie je elektrick nap tie Preverte elektrick obvod poistky Pr stroje je zapnut nie je hmla a n vej rove vody v n dobe na vodu spadla pod po adovan rove Napl te n do...

Page 19: ...r mu recykla n mu stredisku patr te Tento elektrospotrebi nepatr do komun lneho odpadu Spotrebite prispieva na ekologick likvid ciu v robku ZELMER SLOVAKIA spol s r o je zapojen do syst mu ekologickej...

Page 20: ...a v ztart lya res Ne torlaszolja el a p ra kif v t mivel ezzel a berende z st k ros thatja Ne helyezzen el a tart lyban semmilyen gy gyszert illatos t olajat valamint semmilyen m s k miai anya got se...

Page 21: ...van szerelve LCD kijelz s ir ny t panellel valamint a berendez s m k d s t beind t s karbantart gombokkal Minden gomb jelzi az adott m k d s t pus t A vil g t mutat jelzi hogy a berendez s m k dik s...

Page 22: ...n kikapcsol C Be s kikapcsol gomb ON OFF a berendez s elind t s t kikapcsol s t szolg lja Megnyom sakor mel dia hal latszik s a p r s t automatikus m k d si m dba l p Az ON OFF gomb megnyom sa ut n m...

Page 23: ...za a v zk vesed st E D A V ZK VESED S MEGEL Z SE Forralt kih t tt v zzel vagy desztill lt v zzel zemeltesse a p r s t t A v z h m rs klete ne haladja meg a 40 celsiust Minimum hetente egyszer tiszt ts...

Page 24: ...rizze a lentebb eml tett figyelmeztet seket PROBL MA LEHETS GES OK MEGOLD S A kijelz s a m k d si panel nem m k dik nincs p r s k d s kif v s A berendez s nincs ram alatt nem lett bedugva a csatlakoz...

Page 25: ...s kot dobja m anyag gy jt kont nerbe A h l zatb l val kikapcsol s ut n a haszn lt k sz l ket sz tszerelni a m anyag alkatr szeket leadni m sodlagos nyersanyag felv s rl helyen A f m alkatr szeket lead...

Page 26: ...i aparatul n cazul n care recipientul pentru ap este gol Nu bloca i orificiul de evacuare al duzei de aburi deoa rece acest lucru poate duce la deteriorarea aparatului Nu introduce i n rezervor medica...

Page 27: ...e control cu afi aj LCD i butoane prev zute pentru pornirea i utilizarea aparatului Fiecare buton este dotat cu indicator de activare indicatorul luminat informeaz despre faptul c dispozitivul este po...

Page 28: ...v zut pentru por nirea aparatului Dup ap sarea acestuia ncepe melodia umidificatorul de aer se activeaz n modul automat de lucru Indicatoarele de activare de pe butoanele ON OFF AUTO i MODES se lumine...

Page 29: ...pus E D PREVENIRE DEPUNERE PIATR Folosi i ap r cit fiart sau ap distilat Temperatura apei nu trebuie s dep easc 40 C Cur a i recipientul pentru ap suportul umidificatorului traductorul ultrasunet cel...

Page 30: ...a ncepe s se scurg n suportul umidificatorului Descoperire i eliminare defec iuni nainte de a da aparatul la reparat verifica i observa iile enumerate mai jos PROBLEM CAUZ POSIBIL SOLU IE Afi ajul i i...

Page 31: ...cutia de carton duce i o la maculatur pungile din polietilen PE arunca i le n container pentru plastic Aparatul folosit duce i l la punctul de colectare corespunz tor deaorece componentele periculoas...

Page 32: ...36 AH1500 001_v01 Zelmer Zelmer 220 240 80 40 C RU...

Page 33: ...37 AH1500 001_v01 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B ON OFF C MODES D ION E AUTO F G 1 2 3 4 3 6 B 30 II LVD 2006 95 EC EMC 2004 108 EC...

Page 34: ...38 AH1500 001_v01 ON OFF MODES MODES ION ION ION AUTO MODES 1 2 ON OFF ON OFF AUTO MODES 3 ON OFF a C 40 C 5 6 ON OFF ON OFF AUTO MODES 60 RH 60 85 RH MODES 85 RH H RH 60 RH MODES AUTO MODES MODES A...

Page 35: ...39 AH1500 001_v01 ON OFF b 15 3 ON OFF 1 ON OFF 2 3 E 1 ON OFF 2 3 4 5 6 40 C 1 ON OFF 2 50 6 100 30 D...

Page 36: ...40 AH1500 001_v01 3 4 1 2 3 4 5 6 6 F 1 2 3 4 5 6 PE G...

Page 37: ...41 AH1500 001_v01 85 RH H RH 60 RH 12...

Page 38: ...42 AH1500 001_v01 Zelmer Zelmer C 220 240 80 40 BG...

Page 39: ...43 AH1500 001_v01 10 11 12 13 14 15 A LCD B ON OFF C MODES D ION E AUTO F G 1 2 3 4 3 6 40 5 6 B 30 II LVD 2006 95 EC EMC 2004 108 EC A 1 2 3 4 5 6 7 8 9...

Page 40: ...AH1500 001_v01 ION ION AUTO MODES 1 2 ON OFF ON OFF AUTO MODES 3 ON OFF a LCD ON OFF C LCD ON OFF ON OFF AUTO MODES 60 RH 60 85 RH MODES 85 RH H RH 60 RH MODES AUTO MODES MODES ON OFF MODES MODES ION...

Page 41: ...45 AH1500 001_v01 b 15 LCD 3 ON OFF 1 ON OFF 2 3 1 ON OFF 2 3 E D 4 5 6 40 1 ON OFF 2 50 6 100 30 3 4...

Page 42: ...46 AH1500 001_v01 1 2 3 4 5 6 6 F G 1 2 3 4 5 6...

Page 43: ...47 AH1500 001_v01 85 RH H RH 60 RH 12...

Page 44: ...48 AH1500 001_v01 Zelmer Zelmer 220 240 80 40 C UA...

Page 45: ...49 AH1500 001_v01 11 12 13 14 15 A LCD B ON OFF C MODES D ION E AUTO F G 1 2 3 4 3 6 40 C 5 6 B 30 II LVD 2006 95 EC EMC 2004 108 E CE A 1 2 3 4 5 6 7 8 9 10...

Page 46: ...500 001_v01 AUTO MODES 1 2 ON OFF ON OFF AUTO MODES 3 ON OFF a LCD ON OFF b 15 C LCD ON OFF ON OFF AUTO MODES 60 RH 60 85 RH MODES 85 RH H RH 60 RH MODES AUTO a MODES MODES ON OFF MODES MODES ION ION...

Page 47: ...51 AH1500 001_v01 LCD 3 ON OFF 1 ON OFF 2 3 1 ON OFF 2 3 4 E D 5 6 40 C 1 ON OFF 2 50 6 100 30 3 4...

Page 48: ...52 AH1500 001_v01 3 4 5 6 26663 19848 5 40 1 15150 1 2 3 4 5 6 6 1 2 F G...

Page 49: ...53 AH1500 001_v01 85 RH H RH 60 RH 12...

Page 50: ...the appliance emits an unpleasant odor or the appliance emits strange noises turn it off and disconnect the plug from the wall outlet Follow the instructionsmentionedinthechapter Troubleshooting In ca...

Page 51: ...pressed you hear the tune and air humidifier will run in automatic mode Operation indicators on the buttons ON OFF AUTO and MODES will flash and the display shows the level of humidity in the room AU...

Page 52: ...generated steam is being reduced on the MODES button one operation indicator shall fade Above 85 RH production of steam shall be ceased the display shows H RH When the level of humidity in the room dr...

Page 53: ...d remove the scale with a soft cloth 4 Rinse the base of humidifier with clean water and dry it with an absorbent cloth D Be careful that no water gets into the fan outlet electrical components becaus...

Page 54: ...is jammed Remove the water tank from the base and unlock the float switch If the indoor humidity level is higher than 85 RH it will stop producing steam and the display shows H RH When the level of h...