background image

3

General Information 

Standard Use

The ZEISS UVClean is specifically designed for the disinfection of 
ophthalmic frames and lenses by eye care professionals. Tested 
to be safe on frames in standard materials (e.g. zylo, metal, 
plastic, etc.), demo lenses, Rx lenses and frame tags.

Once the ZEISS UVClean is plugged in and turned on, frames 
can be loaded onto the interior rails with lenses facing up and 
temples pointing down. Depending on size of the frames, 
between 6-10 eyeglasses can be loaded.  

A disinfection cycle is started by closing the lid and a pressing 
cycle start button on top of the ZEISS UVClean. LED lights 
illuminate a pulsing blue pattern and the lid automatically locks 
at the start of the cycle. Lights change to solid green and the lid 
unlocks once the 40 second cycle is complete. Eyewear are now 
disinfected.

CAUTION: 

Designed and extensively tested for the 

disinfection of ophthalmic frames and lenses. UVC is 
extremely harmful to living organisms and may cause 
damage to other objects placed in this device. Please use 
extreme caution when using this device for any non-tested 
objects as severe damage to the device and/or object and 
injury to the operator may result if misused.

What it is

The ZEISS UVClean:

• Uses UVC light for the safe and effective disinfection of 

eyeglass frames and lenses.

• Is designed for the unique geometry of eyeglasses to 

prevent (UVC) shadows on frames, lenses, nose pads, and 
temples.  

• Direct UVC illumination ensures thorough exposure which is 

critical for disinfection.

• Requires no calibration.

• Uses UVC bulbs tested to last 30,000 cycles (approximately 3 

years) before requiring replacement.

• Designed for use in the optical dispensary and/or back 

office.

What it is not

The ZEISS UVClean:

• Is NOT a medical device.
• Is NOT intended for sterilization of surgical instruments 

or use during surgery.

• Is NOT intended for the disinfection of opthalmic lenses 

in a hospital or other medical setting.

The ZEISS UVClean Advantage

• Designed exclusively and specifically for the needs of 

eye care professionals

• No liquids
• No disposable waste
• No harsh chemicals
• No mess, no fuss
• Quiet operation
• Easy, one touch operation
• Safe & Gentle on frames
• Fast disinfection in 40 seconds
• ZEISS Branded technology
• The ‘Green Option’
• Consistent disinfection on every cycle
• Lab tested for safety and efficacy
• Uses Ozone-free bulbs with fan
• Standard 1 year warranty
• Made in the USA

Summary of Contents for UVClean

Page 1: ...ZEISS UVClean User Manual www zeiss com UVClean ...

Page 2: ...Table of Contents 3 General Information 4 Package Contents 5 About the ZEISS UVClean 6 Functionality 8 Safety and Operation 8 Cleaning and Recycling 9 Technical Information ...

Page 3: ... objects as severe damage to the device and or object and injury to the operator may result if misused What it is The ZEISS UVClean Uses UVC light for the safe and effective disinfection of eyeglass frames and lenses Is designed for the unique geometry of eyeglasses to prevent UVC shadows on frames lenses nose pads and temples Direct UVC illumination ensures thorough exposure which is critical for...

Page 4: ...4 Package Contents Device UVC Bulb kit and End caps Quick Start Guide Power cord ...

Page 5: ... the sides and in the middle of the bottom chamber Figure 3 Wearing the provided gloves align the two end pins with the slots on the bulb mounts Figure 4 Push the pins fully into the spring load mounts and twist the bulb turn The pins will click into place Repeat for the remaining three bulbs After installing the bulbs slide each cap outward toward the wall of the chamber Figure 5 Install all four...

Page 6: ...and while LED lights are pulsing blue Eye and skin damage may result if lid is opened while LED lights are pulsing blue LED indicator lights Lights along the underside of the lid illuminate colors Figure 8 and patterns to indicate operating conditions Solid Blue Ready to run a disinfection cycle Pulsing Blue Disinfection cycle running Solid Green Disinfection cycle complete Yellow Bulb replacement...

Page 7: ...ndicator still flashes red proceed to Step 3 Step 3 Replace UVC Bulbs Replace all UVC bulbs according to the instructions included in the ZEISS UVClean Ultraviolet C UVC Eyeglass Disinfection Maintenance Kit To order a ZEISS UVClean Ultraviolet C UVC Eyeglass Disinfection Maintenance Kit please contact your ZEISS Business Development Representative or call Customer Service at 1 800 201 4143 CAUTIO...

Page 8: ...fety thresholds Cleaning device Interior To prevent dust buildup within the chamber always keep the ZIESS UVClean lid closed when not in use Never spray or pour liquid cleaners inside the device Exterior The device exterior may periodically be wiped with a soft cloth and mild cleaner Never use harsh chemicals or spray cleaner directly onto the ZEISS UVClean Always spray cleaner onto soft cloth the...

Page 9: ...isionCare_USA Technical Information Specifications Bulbs 4 non ozone generating UVC lamps Dimensions 12 Wide x 12 High x 20 Deep Weight 20 2 lbs Power cord NEMA 5 15 to IEC 320 C13 for use with 120 volt electrical outlets UVClean electrical power input 120 VAC 50 60 Hz 330 W Listed by NRTL MET Canada USA 250V 10A CAUTION HIGH INTENSITY UV LIGHT DO NOT OPERATE WITH LID OPEN ...

Reviews: