INTRODUCTION 

MCU 2008 

Notes on Operational Safety 

Carl Zeiss 

 

 
 

M60-2-0019 e   05/2012 

 

Particular attention must be paid to the following notes: 

 

 

The MCU 2008 is not equipped with any special devices for protection from substances that are 
corrosive, potentially infectious, toxic, radioactive, or otherwise hazardous to health. Make sure 

to observe all legal regulations, particularly the relevant national accident prevention regulations 

when handling such substances. 

 

 

Dust and dirt may impair the performance of the instrument. It must therefore be protected 

against such influences as far as possible. 

 

 

Opening of the instrument is only allowed to accordingly instructed specialists or service staff. 
Operation of the instrument in potentially explosive areas is not allowed. 

 

 

 

Power supply has to be disconnected before opening the instrument and changing the fuses! 
See section 5.2.  

 

Make sure to use only fuses that are in compliance with the specifications contained in the 
Technical Data. The use of makeshift fuses and short-circuiting of the fuse holders are not 

permitted. 

 

 

The manufacturer cannot assume any liability for any other applications, possibly also involving 

individual modules or single parts. This also applies to any service or repair work which is not 

carried out by authorized service personnel. All claims for warranty and warranty services will be 
null and void in any such case. 

 

 

The power plug must be inserted in an outlet featuring a grounding contact. The grounding 
effect must not be made ineffective by an extension cable that does not have a protective 

ground wire. 

 

 

If any protective measures are found to be no longer effective, the instrument must be 

switched off and safeguarded against inadvertent operation. For repair of the instrument, 
please contact a Zeiss service agency or the Carl Zeiss Microscopy Service. 

 

 

Clogged or covered ventilation slats may lead to heat build-up that might damage the 

instrument and, in extreme cases, cause a fire. Always keep the ventilation slats clear and make 
sure that no objects enter the instrument through the ventilation slats. 

 

 

 

 

Defective controls must not be disposed of with household waste; they have to be disposed of 
in compliance with the relevant legal provisions. 

 

Samples have also to be disposed of properly according to the applicable legal provisions and 
internal work instructions. 

 

Summary of Contents for MCU 2008

Page 1: ...Operating Manual MCU 2008 Two Axis Stage Controller...

Page 2: ...oval to do so has been procured Failure to comply will create a liability for compensation of damages All rights are reserved in the event of a patent grant or registration of an industrial design Any...

Page 3: ...1 2 6 Technical Data 12 3 INSTALLATION 13 3 1 Connecting the MCU 2008 13 4 OPERATION 14 4 1 Switching on off 14 4 2 Moving a Sample by means of the Optional Joystick 14 5 MAINTENANCE FUSE CHANGE AND S...

Page 4: ...e with the WEEE Directive 2002 96 EC It is marked with the label This operating manual contains information and warnings that must be followed by the user The following warning and information symbols...

Page 5: ...nufacturer cannot assume any liability for any other applications possibly also involving individual modules or single parts This also applies to any service or repair work which is not carried out by...

Page 6: ...scanning stage is a high precision instrument which can be impaired in its performance or damaged when handled improperly Don t reach into the possible range of travel of the motorized DC stage There...

Page 7: ...INTRODUCTION MCU 2008 Warning and Information Labels Carl Zeiss M60 2 0019 e 05 2012 7 1 2 Warning and Information Labels Fig 1 1 Warning and information labels on the rear side of MCU 2008...

Page 8: ...No warranty is given for defects caused by natural wear wearing parts in particular and improper use The manufacturer is not liable for damage resulting from faulty operation negligence or any other...

Page 9: ...ors d c motors The MCU 2008 supersedes the MCU 28 2 2 Usable Stages Only DC scanning stages tested by Carl Zeiss Micro Imaging GmbH are allowed to be used All DC stages operated by the customer in com...

Page 10: ...w of Unit and Operating Elements 1 ON OFF switch 2 Power connection with fuse compartment 3 Port for X axis of DC XY scanning stage 4 Port for Y axis of DC XY scanning stage 5 Port for joystick use 6...

Page 11: ...the stage used The stage may be operated alternatively by means of the AxioVision software Please see the relevant software operating manual The controller is a CAN component Two CAN ports with equal...

Page 12: ...temperature 10 to 40 C Permissible relative humidity no condensation max 75 at 35 C Atmospheric pressure 800 hPa to 1060 hPa Altitude at installation site max 2000 m Pollution degree 2 Operating data...

Page 13: ...ng stage 5 Port for joystick 5 USB port for PC 6 CAN port for microscope 2x Fig 3 1 Connecting the MCU 2008 Connect the axis cables of the scanning stage to the relevant controller inputs 3 1 2 3 Conn...

Page 14: ...in the direction in which the stage shall travel The wider the lever is displaced the faster the stage will travel Press the switchover knob 4 2 1 integrated in the operator level in order to change...

Page 15: ...strument 5 2 Fuse Change Before changing the fuses it is imperative to disconnect the power plug The fuse holder is located on the back of the MCU 2008 In the event of a fuse failure first the cause m...

Page 16: ...nside the units may only be performed by service staff or specially authorized personnel When service is required please get in touch with your regional representative or with Carl Zeiss Microscopy Gm...

Page 17: ...PROPERTY RIGHTS MCU 2008 Service Carl Zeiss M60 2 0019 e 05 2012 17 6 PROPERTY RIGHTS The instruments units or procedures described in this manual are protected by patents...

Page 18: ......

Reviews: