background image

 

INSTRUMENT DESCRIPTION 

Carl Zeiss 

Technical Data 

MCU 2008 

 

 
 

12 

 

M60-2-0019 e   05/2012 

2.6

 

Technical Data 

Dimensions (width x depth x height) 

MCU 2008 .................................................................................... approx. 250 mm x 220 mm x 100 mm 
 

Weight 

MCU 2008 ........................................................................................................................ approx. 2.5 kg 
Joystick ............................................................................................................................. approx. 0.4 kg 
Mechanical stage .............................................................................................................. approx. 4.0 kg 
 

Ambient conditions 
Transportation (in packaging): 

Permissible ambient temperature .................................................................................... -40 to +70 °C 

Storage: 

Permissible ambient temperature ................................................................................... +10 to +40 °C 
Permissible relative humidity (no condensation) ..................................................... max. 75 % at 35 °C 

Operation: 

Permissible ambient temperature ................................................................................... +10 to +40 °C 
Permissible relative humidity (no condensation) ..................................................... max. 75 % at 35 °C 
Atmospheric pressure ......................................................................................... 800 hPa to 1060 hPa 
Altitude at installation site ............................................................................................... max. 2000 m 
Pollution degree ............................................................................................................................... 2 

 

Operating data 

Intended site ....................................................................................................................... closed rooms 
Protection class ...................................................................................................................................... I 
Protection type ................................................................................................................................ IP 20 
Electrical safety............................................................ in compliance with DIN EN 61010-1 (IEC 61010-1) 
 .......................................................................................... under consideration of CSA and UL directives 
Overvoltage category............................................................................................................................. II 
Radio interference suppression ......................................................... in accordance with EN 55011 class B 
Noise immunity .................................................................................... in accordance with DIN EN 61326 
Line voltage ............................................................................................................ 100 to 240 V ±10 % 

 ............................................................................ 

Change of instrument voltage setting is not necessary! 

Line frequency........................................................................................................................... 50/60 Hz 
Power consumption .............................................................................................................. max. 50 VA 

 

Fuses according to IEC 127  .......................................................................................... T 2.0 A/H / 250 V 
 

Summary of Contents for MCU 2008

Page 1: ...Operating Manual MCU 2008 Two Axis Stage Controller...

Page 2: ...oval to do so has been procured Failure to comply will create a liability for compensation of damages All rights are reserved in the event of a patent grant or registration of an industrial design Any...

Page 3: ...1 2 6 Technical Data 12 3 INSTALLATION 13 3 1 Connecting the MCU 2008 13 4 OPERATION 14 4 1 Switching on off 14 4 2 Moving a Sample by means of the Optional Joystick 14 5 MAINTENANCE FUSE CHANGE AND S...

Page 4: ...e with the WEEE Directive 2002 96 EC It is marked with the label This operating manual contains information and warnings that must be followed by the user The following warning and information symbols...

Page 5: ...nufacturer cannot assume any liability for any other applications possibly also involving individual modules or single parts This also applies to any service or repair work which is not carried out by...

Page 6: ...scanning stage is a high precision instrument which can be impaired in its performance or damaged when handled improperly Don t reach into the possible range of travel of the motorized DC stage There...

Page 7: ...INTRODUCTION MCU 2008 Warning and Information Labels Carl Zeiss M60 2 0019 e 05 2012 7 1 2 Warning and Information Labels Fig 1 1 Warning and information labels on the rear side of MCU 2008...

Page 8: ...No warranty is given for defects caused by natural wear wearing parts in particular and improper use The manufacturer is not liable for damage resulting from faulty operation negligence or any other...

Page 9: ...ors d c motors The MCU 2008 supersedes the MCU 28 2 2 Usable Stages Only DC scanning stages tested by Carl Zeiss Micro Imaging GmbH are allowed to be used All DC stages operated by the customer in com...

Page 10: ...w of Unit and Operating Elements 1 ON OFF switch 2 Power connection with fuse compartment 3 Port for X axis of DC XY scanning stage 4 Port for Y axis of DC XY scanning stage 5 Port for joystick use 6...

Page 11: ...the stage used The stage may be operated alternatively by means of the AxioVision software Please see the relevant software operating manual The controller is a CAN component Two CAN ports with equal...

Page 12: ...temperature 10 to 40 C Permissible relative humidity no condensation max 75 at 35 C Atmospheric pressure 800 hPa to 1060 hPa Altitude at installation site max 2000 m Pollution degree 2 Operating data...

Page 13: ...ng stage 5 Port for joystick 5 USB port for PC 6 CAN port for microscope 2x Fig 3 1 Connecting the MCU 2008 Connect the axis cables of the scanning stage to the relevant controller inputs 3 1 2 3 Conn...

Page 14: ...in the direction in which the stage shall travel The wider the lever is displaced the faster the stage will travel Press the switchover knob 4 2 1 integrated in the operator level in order to change...

Page 15: ...strument 5 2 Fuse Change Before changing the fuses it is imperative to disconnect the power plug The fuse holder is located on the back of the MCU 2008 In the event of a fuse failure first the cause m...

Page 16: ...nside the units may only be performed by service staff or specially authorized personnel When service is required please get in touch with your regional representative or with Carl Zeiss Microscopy Gm...

Page 17: ...PROPERTY RIGHTS MCU 2008 Service Carl Zeiss M60 2 0019 e 05 2012 17 6 PROPERTY RIGHTS The instruments units or procedures described in this manual are protected by patents...

Page 18: ......

Reviews: