13 - EN
2.7.3 P menus for the installer
Menus with a line at minimum and maximum value are Reading menus.
Menu P3
¨
Setting ventilation programmes
Ventilation programme values
submenu
description
Minimum
Maximum
General
reset
P30
Setting the capacity (in %) of the
exhaust fan in
absent
position
.
0% or 15%
97%
nL / HL
15% / 15%
P31
Setting the capacity (in %) of the
exhaust fan in
low
position
.
16%
98%
nL / HL
35% / 40%
P32
Setting the capacity (in %) of the
exhaust fan in
medium
position
.
17%
99%
nL / HL
50% / 70%
P33
Setting the capacity (in %) of the
exhaust fan to
high
position
.
18%
100%
nL / HL
70% / 90%
P34
Setting the capacity (in %) of the
supply fan to
absent
position
.
0% or 15%
97%
nL / HL
15% / 15%
P35
Setting the capacity (in %) of the
supply fan in
low
position
.
16%
98%
nL / HL
35% / 40%
P36
Setting the capacity (in %) of the
supply fan in
medium
position
.
17%
99%
nL / HL
50% / 70%
P37
Setting the capacity (in %) of the
supply fan in
high
position
.
18%
100%
nL / HL
70% / 90%
P38
Current capacity (in %) of the
exhaust fan.
-
-
Current %
P39
Current capacity (in %) of the
supply fan.
-
-
Current %
Menu P4
¨
Reading the temperatures
Temperature values
submenu
description
Minimum
Maximum
General
reset
P40
Current value of Tah
(= afterheater temperature)
-
-
Current
o
C
P41
Comfort temperature
12
o
C
28
o
C
20
o
C
P44
Current value of Tch
(= extractor hood temperature)
-
-
Current
o
C
P45
Current value of T1
(= outside air temperature)
-
-
Current
o
C
P46
Current value of T2
(= supply air temperature)
-
-
Current
o
C
P47
Current value of T3
(= return air temperature)
-
-
Current
o
C
P48
Current value of T4
(= exhaust air temperature)
-
-
Current
o
C
P49
Current value
t
ge
(= outside air temperature
for the geothermal heat exchanger)
-
-
Current
o
C