background image

   1 - EN

    1 - EN

 

Preface

 Carefully read this manual before use.

   

This manual provides all the information required for safe 
and optimal installation and maintenance of the Com-
foAir 160. It is also intended as a reference  for servicing, 
so that this can be carried out in a responsible manner. 
The device is subject to continuous development and 
improvement. As a result, the ComfoAir 160 may slightly 
differ from the descriptions.

NOTE

This manual has been compiled with  

the utmost care. However, no rights can be 

derived from it. In addition, we at all times 

reserve the right to change the contents of 

this manual, without prior notice.

1  Introduction

The device's name is ComfoAir 160. In the following man-
ual it will be referred to as ComfoAir.
The ComfoAir is a balanced ventilation system with heat 
recovery in order to create healthy, balanced and ener-
gy-efficient  ventilation  in  houses.  The  ComfoAir  has  a 
CE marking on the identification plate. The identification 
plate can be found on top of the ComfoAir.

1.1   Warranty and liability

1.1.1   Guarantee conditions

The ComfoAir is covered by a manufacturer’s warranty 
for a period of 24 months after fitting up to a maximum 
of 30 months after the date of manufacture. Warranty 
claims may only be submitted for material faults and/or 
construction faults arising during the warranty period. In 
the case of a warranty claim, the ComfoAir must not be 
dismantled without written permission from the manu-
facturer. Spare parts are only covered by guarantee, if 
they were supplied by the manufacturer and have been 
installed by an approved installer.

The warranty becomes invalid if:

•   The guarantee period has elapsed;

• 

The device is used without filters;

• 

Parts are used that have not been supplied by the 
manufacturer;

• 

Non-authorised changes or modifications have been 
made to the unit.

1.1.2   Liability

The ComfoAir has been designed and manufactured for 
use in balanced ventilation systems incorporating Zeh-
nder heat recovery systems. Any other application is seen 
as inappropriate use and can result in damage to the 
ComfoAir or  personal injury, for which the manufacturer 
cannot be held liable. The manufacturer is not liable for 
any damage originating from:
•  Non-compliance with the safety, operating and main-

tenance instructions in this manual;

• 

The use of components not supplied or recommend-
ed by the manufacturer.

 

Responsibility for the use of such components lies 
entirely with the installer;

• 

Normal wear and tear.

Summary of Contents for ComfoAir 160

Page 1: ...ComfoAir 160 User manual...

Page 2: ...has been compiled with the utmost care The publisher cannot be held liable for any damage caused as a result of miss ing or incorrect information in this manual In case of disputes the Dutch version...

Page 3: ...CO2 sensor 6 2 2 5 CC Ease panel 6 2 3 operating the CC Ease panel 7 2 3 1 Setting the date and time 7 2 3 2 Reading and setting the comfort temperature 7 2 3 3 Reading and setting the ventilation vo...

Page 4: ...EN IV EN IV...

Page 5: ...24 months after fitting up to a maximum of 30 months after the date of manufacture Warranty claims may only be submitted for material faults and or construction faults arising during the warranty per...

Page 6: ...p this manual with the ComfoAir throughout its life Instructions with regard to cleaning or replacing the filters on the intake and exhaust valves must be care fully observed The specifications stated...

Page 7: ...and outgoing air the ComfoAir also provides the benefits of heat recovery Heat recovery means that heat from the extracted air is transferred to the fresh and usually colder air from outside the build...

Page 8: ...U comfort temperature Shown in display 1 A 2 3 X X X X Ventilation setting absent 1 A 2 3 X X X X Ventilation setting low 1 A 2 3 X X X X Ventilation setting medium 1 A 2 3 X X X X Ventilation setting...

Page 9: ...itches vary widely in model and are therefore not il lustrated here If required the bathroom switch can be turned on and off using a time delay entered via a digital operating device delay timer This...

Page 10: ...ds READ Press for longer than 2 seconds SET This button allows you to programme two settings Press for less than 2 seconds Programme ventilation setting AUTO MANUAL Press longer than 2 seconds Program...

Page 11: ...fly Wait until the comfort temperature appears 2 Press to return to the main screen Setting the comfort temperature 1 Press longer than 2 seconds Wait until the comfort temperature e g 20 0 starts bli...

Page 12: ...lation volume can be set as follows 1 Press to increase the ventilation volume 2 Press to decrease the ventilation volume During manual ventilation the CC Ease panel will not dis play AUTo but MANUAL...

Page 13: ...Wait until the programme position e g 1 starts blinking 5 Select the desired programme position using or 6 Press Wait until the hour e g 7 starts blinking 7 Select the desired start time in hours usin...

Page 14: ...enu using or e g P sub menu 23 5 Press Entering settings in P menus The minimum and maximum values for the available parameters are preset in the software 6 Select a new value for the programme using...

Page 15: ...rating the bathroom switch the ComfoAir switches back to the normal setting Low voltage input 0 Min 120 Min 30 Min P23 Optional Note only applies to systems fitted with a hardwired 3 position switch O...

Page 16: ...pplies to systems fit ted with a CC Ease panel Time for the Boost setting After pressing continuosly 2 sec on the CC Ease panel the ComfoAir will switch to the high setting for x minutes and then auto...

Page 17: ...time it is recommended to replace the filters and clean the valves first During the construction phase the ventilation system could have become dirty with building dust 2 4 2 Cleaning the valves in yo...

Page 18: ...mmunication has been estab lished Subsequently in the event of a malfunction or filter dirty alert both indicators will flash red 3 times After that both indicators will light up green once more 2 5 3...

Page 19: ...94 Company register Zwolle 05022293 EEC declaration of conformity Machine description heat recovery units ComfoAir 160 series Complies with the following directives Machinery Directive 2006 42 EEC Low...

Page 20: ...Zehnder Group Nederland B V Lingenstraat 2 8028 PM Zwole Nederland Tel 038 429 69 11 Fax 038 422 56 94 Internet www jestorkair nl E mail info jestorkair nl Zehnder Group Nederland B V 849050968 0112...

Reviews: