EN - 12
Time delay values
Sub-menu
description
Minimum
Maxi-
mum
General
reset
P26
Note:
only applies to systems fit-
ted with an rF switch.
Overrun timer for ventilation setting 3 " using
".
• After pressing "
"
continuously
(> 2 sec.), the
ComfoAir will switch to the
high
setting for ‘x’
minutes and then automatically returns to the
normal
setting.
If any 3-position switch is operated during this lag-
ging time the ComfoAir will instantly revert to the
ventilation position as set at that time.
1 Min.
120 Min. 30 Min.
P27
Note:
only applies to systems fit-
ted with a CC Ease panel.
Time for the Boost setting.
• After pressing “
” continuosly (>2 sec.) on the
CC Ease panel, the ComfoAir will switch to the
high setting for 'x' minutes and then automatically
returns tot the NORMAL setting
If any 3-position switch is operated during this lag-
ging time the ComfoAir will instantly revert to the
ventilation position as set at that time.
0 Min.
120 Min. 30 Min.
Menu P9
¨
Status of programmes (from menu P5 and P6 additional programmes)
Status
Sub-menu
description
Activated
P90
Open fire programme active?
Yes (1) / No (0)
P91
Bypass Open?
Yes (1) / No (0)
P94
Analogue input (0-10V) active?
Yes (1) / No (0)
P95
Frost protection active?
Yes (1) / No (0)
P97
Enthalpy programme active?
Yes (1) / No (0)