Declaration of Performance

Supplier Name or Trade Mark

Supplier Model Identifier and Options Installed

SEC in [kWh/(m

2

a)] for Each Climate

(Cold, Average, Warm)

SEC Class
(Cold, Average, Warm)

Declared Typology

Type of Motor Drive Installed

Type of Heat Recovery

1

Heat Recovery Efficiency

2

Maximum Flow Rate in (m

3

/h) / (l/s)

3

Electric Power Input at Maximum Flow Rate (W)

4

Sound Power Level (L

WA

) in dB(A))

5

Reference Flow Rate in (m

3

/h) / l/s)

6

Reference Pressure Difference

SPI in [W/(m

3

/h)]

7

Control Factor and Typology

Declared Maximum Internal and External Leakage (%)

8

Position and Description of Visual Filter Warning

Internet Address for Preassembly / Disassembly Instructions

AEC (kWh electricity/a) for Each Climate
(Cold, Average, Warm)

AHS (kWh electricity/a) for Each Climate
(Cold, Average, Warm)

Greenwood Airvac

Manual Control

(via manual switch)

-30.1

-13.7

-4.3

B

E

F

Unidirectional

Multi-Speed

None

n/a

347 / 97

58

52

245 / 68

50

0.11

1

Internal: n/a

External: n/a

n/a

www.greenwood.co.uk

3.5

3.5

3.5

33.6

17.2

7.8

Greenwood Airvac

Local Demand Control

(with 2 or more sensors)

-53.6

-26.5

-11.0

A+

B

E

Unidirectional

Multi-Speed

None

n/a

347 / 97

58

52

245 / 68

50

0.11

.65

Internal: n/a

External: n/a

n/a

www.greenwood.co.uk

1.8

1.8

1.8

55.4

28.3

12 .8

Greenwood Airvac

Central Demand Control

(with 1 sensor)

-40.2

-19.2

-7.2

A

E

F

Unidirectional

Multi-Speed

None

n/a

347 / 97

58

52

245 / 68

50

0.11

.85

Internal: n/a

External: n/a

n/a

www.greenwood.co.uk

2.7

2.7

2.7

42.9

21.9

9.9

Greenwood Airvac

Clock Control

(via 7 day timer control)

-33.5

-15.5

-5.3

B

E

F

Unidirectional

Multi-Speed

None

n/a

347 / 97

58

52

245 / 68

50

0.11

.95

Internal: n/a

External: n/a

n/a

www.greenwood.co.uk

3.2

3.2

3.2

36.7

18.7

8.5

Declaration of Performance

Residential Ventilation Unit Greenwood Centair CMEV.4

1. Type of Heat Recovery: Recuperative is without humidity recovery and renewable is with humidity recovery.

2.  Efficiency according to EN13141-7:2010 at reference airflow rate @50Pa; and according to EN13141-8:2014 systems without connection.

3. Maximim flow at 100 Pa external pressure (shown in both m

3

/h and l/s).

4. Electrical power input at the maximum airflow rate (Watts).

5. Casing noise radiation at reference flow rate at 50Pa external pressure. 

6. Reference flow rate is 70% of the maximim airflow at 50Pa external pressure according to EN13141-7:2010 (shown in both m

3

/h and l/s).

7. In accordance with EN13141-7:2010 at reference flow rate.

8. In accordance with EN13141-7:2010 at reference flow rate and EN13141-8:2014 systems without connection.

SEC:  Specific Energy Consumption

SPI: Specific Power Input

AEC: Annual Electricity Consumption

AHS: Annual Heating Saved 

Summary of Contents for Centair CMEV.4

Page 1: ...EV 4 CMEV 4e CMEV 4eHT Mechanical Extract Ventilation MEV System User Homeowner Guide Commissioning and Inspection Record Located on page 5 of this guide should have been completed by the Commissionin...

Page 2: ...uarantee Warranty Information 12 Contents Overview Your home has a continuously running ventilation MEV system installed This consists of a central extract system that is linked by a network of ducts...

Page 3: ...open flued oil or gas fuelled appliance is installed precautions must be taken to avoid a back flow of gases into the room If the supply cord is damaged it must be replaced by a special cord assembly...

Page 4: ...ement For installations where the unit is hidden behind a panel we recommend a minimum size access panel of 600mm2 This is to ensure that the ducts can be disconnected and reattached with ease See Fig...

Page 5: ...o the installation of which should be incorporated into the Home Information Pack for the homeowner to keep Part 1 System details and declarations Part 2a Installation details Part 2b Inspection of in...

Page 6: ...l internal doors have sufficient undercut to allow air transfer between rooms i e 10 mm over and above final floor finish Has all protection packaging been removed including from background ventilator...

Page 7: ...Inspection completion Yes No Measured Air Flow High Rate l s Design Air Flow High Rate l s Refer to Table 5 1a ADF Measured Air Flow Low Rate l s Design Air Flow Low Rate l s Refer to Table 5 1a in AD...

Page 8: ...turer s recommendations Have all distribution grilles been locked to prevent unauthorised adjustment 3 6 Test Engineer s Details Name Company Address Line 1 Address Line 2 Telephone Number Post Code S...

Page 9: ...8 1 8 55 4 28 3 12 8 Greenwood Airvac Central Demand Control with 1 sensor 40 2 19 2 7 2 A E F Unidirectional Multi Speed None n a 347 97 58 52 245 68 50 0 11 85 Internal n a External n a n a www gre...

Page 10: ...12 8 Greenwood Airvac Central Demand Control with 1 sensor 41 6 20 6 8 6 A D F Unidirectional Variable Speed None n a 352 98 36 51 245 68 50 0 06 85 Internal n a External n a n a www greenwood co uk 1...