Depending on the way your MEV unit has been installed, the specific operation of your fan may vary. The unit 
has three speeds available, but may not have been wired to use them all. Options are – 

1)

Trickle Speed: 

Operating on a continual basis.

2)

Medium Speed:   

Activated manually using our GS1 switch or similar.

3)

Boost Speed:       

Activated manually using our GS1 / GS2 switch or similar.

Note; Not all three speeds may be operational. Medium speed may be disconnected (when using a GS2 switch
or similar).

Note; Other manufacturers switches may show different markings.

To maintain good indoor air quality within the dwelling it is important that the ventilation system remains in 
operation at all times unless powered down periodically for maintenance/repair.

Depending on when your home was built, background window trickle ventilators may be provided in dry habitable
rooms.  Trickle vents should not be installed in the same rooms as the mechanical extract valves, as overall 
ventilation effectiveness can be reduced.

Warning: 

This appliance can be used by children aged from 8 years and above and persons with

reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the appliance in safe way and understand the
hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not
be made by children without supervision.

Where an open-flued oil or gas-fuelled appliance is installed, precautions must be taken to avoid a
back-flow of gases into the room.

If the supply cord is damaged, it must be replaced by a special cord/assembly available
from the manufacturer or its service agent. The replacement must be carried out by a 
qualified Electrician in accordance with IEE or local regulations.

SMART Technology - CMEV.4eHT Only

To maintain a healthy indoor environment the CMEV.4eHT includes SMART technology for Over-run Timer
(Greenwood TimerSMART

TM

) and Humidity (Greenwood HumidiSMART

TM

).

Greenwood TimerSMART

TM

monitors the length of time that there is an occupancy presence within a wet-room

and provides a fixed over-run time period to best match the length of time that the ‘switch live’ is active (as
shown below):

Greenwood HumidiSMART

TM

monitors the ambient humidity within the wet-room environment and looks for

short peaks of humidity made by either showering or bathing.  This SMART technology ensures that your
CMEV.4eHT is not on boost for prolonged periods of time due to the higher ambient humidity levels caused 
during the hot summer months.

To disassemble the unit, disconnect from mains supply and use a screwdriver to segregate the 
electronic components and motor from the plastic housing. Dispose items in accordance with WEEE.

2.1.1

2.1.2

2.1.3

2.1.4

2.1.5

2.1.6

2.1.7

2.1.8

2.0

General Overview

Time ‘Switch Live’ is Active

Over-run Boost Period

0 –   5 minutes

No over-run

5 – 10 minutes

5 minutes

10 – 15 minutes

10 minutes

15+ minutes

15 minutes

II

I

II

I

GS2 switch markings - 

Trickle (I) & Boost (II)
Operation

GS1 switch markings - 

Trickle (Centre), Medium (I) 
& Boost (II) Operation

Summary of Contents for Centair CMEV.4

Page 1: ...EV 4 CMEV 4e CMEV 4eHT Mechanical Extract Ventilation MEV System User Homeowner Guide Commissioning and Inspection Record Located on page 5 of this guide should have been completed by the Commissionin...

Page 2: ...uarantee Warranty Information 12 Contents Overview Your home has a continuously running ventilation MEV system installed This consists of a central extract system that is linked by a network of ducts...

Page 3: ...open flued oil or gas fuelled appliance is installed precautions must be taken to avoid a back flow of gases into the room If the supply cord is damaged it must be replaced by a special cord assembly...

Page 4: ...ement For installations where the unit is hidden behind a panel we recommend a minimum size access panel of 600mm2 This is to ensure that the ducts can be disconnected and reattached with ease See Fig...

Page 5: ...o the installation of which should be incorporated into the Home Information Pack for the homeowner to keep Part 1 System details and declarations Part 2a Installation details Part 2b Inspection of in...

Page 6: ...l internal doors have sufficient undercut to allow air transfer between rooms i e 10 mm over and above final floor finish Has all protection packaging been removed including from background ventilator...

Page 7: ...Inspection completion Yes No Measured Air Flow High Rate l s Design Air Flow High Rate l s Refer to Table 5 1a ADF Measured Air Flow Low Rate l s Design Air Flow Low Rate l s Refer to Table 5 1a in AD...

Page 8: ...turer s recommendations Have all distribution grilles been locked to prevent unauthorised adjustment 3 6 Test Engineer s Details Name Company Address Line 1 Address Line 2 Telephone Number Post Code S...

Page 9: ...8 1 8 55 4 28 3 12 8 Greenwood Airvac Central Demand Control with 1 sensor 40 2 19 2 7 2 A E F Unidirectional Multi Speed None n a 347 97 58 52 245 68 50 0 11 85 Internal n a External n a n a www gre...

Page 10: ...12 8 Greenwood Airvac Central Demand Control with 1 sensor 41 6 20 6 8 6 A D F Unidirectional Variable Speed None n a 352 98 36 51 245 68 50 0 06 85 Internal n a External n a n a www greenwood co uk 1...

Page 11: ...11...

Page 12: ...on request from 44 0 1276 408404 or www greenwood co uk info greenwood co uk All information is believed correct at time of going to press E OE All goods are sold according to Zehnder Group UK Ltd s...

Reviews: