1.4 Range of application
The pump FSP is adapted for slightly polluted liquids with suspended solids (no stones) up to a particle
size of 1 mm, but not for excrement containing sewage! It is especially adapted for the exhaustion of
water up to approx. 1 mm. When starting the pumping process, the water level must amount to approx.
1,5 cm.
1.5 Accessories
The pumps are delivered with a hose connection piece with a nut connector for a 1” hose (diameter 25
mm). The electronic level control with electrodes is available as optional accessory.
2. Safety:
(from:“VDMA sheet 24 292“)
The operation manual at hand provides basic notes which must be taken into account during
assembly, operation and maintenance works. Therefore, before assembly and commissioning, this
operation manual must be read by the assembler as well as by the responsible personnel/operator at
all costs. It always must be available on site of operation of the device.
The general safety notes listed under the main point safety are not the only notes to be taken into
account. Please also observe the specific safety instructions, such as those for private use, listed
under other main points.
2.1 Marking of the notes contained in the operation manual
The safety notes contained in this operation manual which can cause danger to persons are
specifically marked by the following general danger symbol
Safety sign according to DIN 4844 - W 9,
The following symbol warns against dangers caused by voltage
Safety sign according to DIN 4844 - W 8.
In case of safety notes the non-observance of which can cause danger to the device and its
functioning, the word ATTENTION! is inserted.
Notes that are directly attached to the device, such as - Arrow indication the direction of rotation
- Characteristics of liquid connections
must be observed and kept in completely readable condition at all costs.
2.2 Personnel development and training
The personnel responsible for operation, maintenance, inspection and assembly must have the
corresponding qualifications for those types of work. Area of responsibility, competence and the
surveillance of the personnel must be regulated precisely by the operator. If the personnel do not
possess the necessary knowledge, they must be trained and instructed. By order of the operator of the
pump, the instruction and training, if necessary, can be carried out by the manufacturer/supplier.
Furthermore the operator must make sure that the personnel have completely understood the content
of the operation manual.
2.3 Dangers in case of non-observance of the safety notes
The non-observance of the safety notes can cause dangers to persons as well as to the environment
and the machine. If the safety notes are not observed, this can result in the loss of all compensation
claims.