Start Of Configuration
Data Transmit Method
The data transfer method includes three types: Normal (default), Out-of-Range Mode, and
Batch Mode. Users may modify this setting according to their preferences.
Normal
When the scanner is within the connection range, the scanned data will be transferred to
the host computer immediately. If the scanner is out of its connecting range, the scanner
does not send or store any data.
Data transmit normal
Out of Range
Scanned data are stored when scanner is out of its wireless communication range. When
scanner is back into its communication range or re-connected, the stored data are sent
when scanning next barcode label.
Out of range buffer enable
Batch Mode
Whether within the connection range or not, in batch mode, the scanner stores all
scanned data that will be transferred to the host computer after scanning “Send Batch
Data” label. Number of storable bar codes = 61,365 bytes of memory / (number of
characters in the bar code +2)
Batch mode enable
28
End Of Configuration