2. Diameter of rebar
Setting diameter of tested rebar, the settable range is between 6 and
50mm, and the default value is the setting value of previous stored
object.
Pressing
【
a
】
,
【
b
】
in figure 3-7 to shift cursor to Dia., then press
【
ENTER
】
to set the diameter, pressing
【
a
】
or
【
b
】
key can
increase or decrease by 1 rebar standard. Long time pressing of
【
a
】
or
【
b
】
key can increase or decrease the value consecutively. After it
is done, pressing
【
SAVE
】
or
【
ENTER
】
for storage, cursor will
disappear and go back to parameter setting interface automatically.
3. Thickness
design
Setting the thickness of tested concrete cover, settable range is
10-99mm; the default value is the set one of previous stored object.
Pressing
【
a
】
,
【
b
】
in figure 3-7 to shift cursor to Cover, then press
【
ENTER
】
to set the thickness of cover, pressing
【
a
】
or
【
b
】
for once can increase or decrease by one and long time pressing of
these two keys, the value increase or decrease consecutively. After it is
done, pressing the
【
SAVE
】
or
【
ENTER
】
, cursor will disappear and
go back to parameter setting interface as shown in figure 3-7.
4. Object
type
The tested object type can be divided into 2, beam or floor. It is used
for evaluation of excessiveness of tested thickness value
automatically.
Pressing
【
a
】
,
【
b
】
in figure 3-7 to shift cursor to Type, then press
【
ENTER
】
to set the type, pressing
【
a
】
and
【
b
】
for the shift.
After it is done, pressing the
【
SAVE
】
or
【
ENTER
】
, cursor will
disappear and go back to parameter setting interface.
5. Minimum
thickness
Setting of the minimum thickness of cover allowed by tested rebar in
quick check; range is 0-99mm, default value is 0mm. When using