ZBA Inc
.
ZBA, Inc.
94 Old Camplain Road Hillsborough, NJ 08844
Ph: 908-359-2070 Fax: 908-595-0909
Web: http://www.zbausa.com/
Command
Response
Parameters
AT+ STOPBIT=<Para1>\r\n
OK
<Para1>
:
1: 1 Stop bit
2: 2
Stop bits
Default:
1
stop bit
AT+ STOPBIT?\r\n
OK
\r\n
+
STOPBIT
:
<Para1>\r\n
9.7
Instruction 7: set / query port parity
Command
Response
Parameters
AT+ VERIFYBIT=<Para1>\r\n
OK
<Para1>
:
0: no parity
1: odd parity
2: even parity
Default:
0
AT+ VERIFYBIT?\r\n
OK
\r\n
+
VERIFYBIT
:
<Para1>\r\n
9.8
Instruction 8: Set / Query the device type
Command
Response
Parameters
AT+ ROLE=<Para1>\r\n
OK
<Para1>:
0: The central node
1: The routing node
2: The terminal node
Default: 1
AT+ ROLE?\r\n
OK
\r\n
+
ROLE
:
<Para1>\r\n
9.9
Instruction 9: Set / query the network ID
Command
Response
Parameters
AT+ PANID=<Para1>\r\n
OK
<Para1>
:
0000 ~ 3FFF
Default:
AT+ PANID\r\n
OK
\r\n
+
PANID
:
<Para1>\r\n
\
9.10
Command 10: Set / query the communication channel
Command
Response
Parameters
AT+ CHANNEL=<Para1>\r\n
OK
<Para1>
:
0 ~ 15
Default:
AT+ CHANNEL\r\n
OK
\r\n
+
CHANNEL
:
<Para1>\r\n
Communication channel
Channel / Frequency
Remarks
0~15
00
/
2.405GHz
It is recommended to use channels 4, 9, 14, 15
to avoid
interference with any local WIFI.