Indicator LED status
Description
Operating
instructions
(port =P10)
LED indicator will
flash once each second
The system operating normally
LED indicator is
illuminated constantly
The module is in the configuration set-
up mode.
LED indicator is Off System is not running, indicating a
power or system failure
Network
instructions
(port = P11)
LED indicator is Off Central node
(coordinator)
A successful
network has been
created
Routing node
The node has Join
the network
Terminal node
The node has Join
the network
Always
Not connected to the network
Figure 7-2 Table of Indicator LED function
7.3
Data Interface
The Zigbee module can be operated via communication to a standard UART function with either a four (4)
wire + ground UART connection (TX, RX, RTS, CTS, GND ) or a two (2) wire +ground UART
connections (TX, RX, GND)
The default data interface parameters:
Serial port parameters
Default
Baud Rate
9600
Parity
NONE
Data bits
8
Stop bit
1
Figure 7-3 Table of default communication parameters