Zaxcom TRXLA3 ZaxNet Menu
18
IFB Receive Pulse Set
This menu will only appear if the TRXLA3 is set to go into transmit in the RX to TX Time menu
This menu sets the interval that the ZaxNet transceiver will stop sending confidence audio and search for time
code.
When enabled the pulse setting tells the ZaxNet transceiver to leave ZaxNet transmit mode once every XXX
seconds and go into receive mode so it can re-jam its time code wirelessly via ZaxNet. This setting would be
used so the TRXLA3 could update its time code while monitoring audio via an ERX receiver. Please note when
the ZaxNet transceiver searches for ZaxNet it will temporally go out of transmit mode for approximately 1
second as it searches for ZaxNet time code. The settings are NEVER or any interval between 5 and 999 seconds.
Record Beep Set
This menu will only appear if the TRXLA3 is set to transmit (TX) mode
When the record beep is set to ON, and the TRXLA3 is recording, the confidence audio sent to the ERX via
ZaxNet will have an audible beep, in variable intervals, giving conformation that the TRXLA3 is indeed
recording. The beeps will only be heard in the ERX and will not be recorded on the card, or be sent to the UHF
receiver. The intervals can be set between 2 to 18 seconds in 2 second increments.
The ZaxNet transceiver will stay in transmit mode and never go into
receive mode.
In this example the ZaxNet transceiver will go out of transmit mode
every 10 minutes. This setting would be used so the TRX could
update its time code while monitoring audio via an ERX receiver.
ZAXNET RX PULSE:
OFF
IFB RX PULSE
600 SECS
ZNET RECORD BEEP
OFF