5. MAINTENANCE

6. COMMON FAULTS AND TROUBLESHOOTING

5.1. Machine cleaning

Turn off the power supply of the machine and wipe the machine with a soft semi dry rag. Do not use 

chemical reagents, such as benzene, alcohol, gasoline, etc. Otherwise, the air conditioning surface will 

be damaged, or even the whole machine will be damaged. Do not let water splash into the machine.

6.1. Intelligent Fault Detection

5.4. Seasonal maintenance

If you do not use the machine for a long time, please follow the steps below to maintain it:

• Drain the water from the tank.

• Clean and reinstall the filter screen

• Cover the machine with plastic bags and place it in a cool and dry place.

If it is not used for a long time, please pay attention to the following points when using it again:

• Confirm whether there is water in the water tank or whether the water volume meets the requirements. 

There will be a prompt when you start the machine. Please follow the prompt.

• Check whether the power cord is in good condition. Do not use it if it is damaged.

Knob

Air inlet grille

Filter screen

5.2. Filter screen cleaning

Unscrew the two knobs of water inlet and water outlet from 

the rear side, then remove the rear air inlet grille, and remove 

the filter screen from the rear air inlet grille for cleaning. Put 

the filter screen into clean water or warm water (about 40°C) 

which has been added with neutral detergent, and then place 

it in dry air to dry naturally, and then reinstall the filter screen.

NOTE: a). Do not use water with too high temperature (suitable 
temperature is about 40°C) or irritant detergent (such as 

alcohol, gasoline, benzene, etc.) to clean the filter screen;

 

 b). In order to avoid the deformation of the filter screen, 

the cleaned filter screen should be kept away from the heat 

source and put in the dry air to dry naturally;

 

 c). It is recommended to clean the filter screen once 

every two weeks.

5.3. Filter screen cleaning

It  is  recommended  to  replace  the  water  in  the  water  tank 

through drainage / water inlet at least every quarter.

Fault Code

E1

E2

Code Meaning

Water shortage of water 

tank

Please connect the water inlet 

pipe and press the

[water inlet] key to feed water

Please connect the drain pipe 

and press the [drain] key

to drain

Water tank is full

Solution

Summary of Contents for ZPAC 09

Page 1: ...IUNI DE FOLOSIRE NAINTE DE A UTILIZA APARATUL A G P HASZN LATA EL TT ALAPOSAN OLVASSA EL EZT A HASZN LATI UTAS T ST ZASS Romania SRL CUI RO15328988 Ungheni nr 40 A cod 547605 Mure Telefon 0265 262870...

Page 2: ...1 2 3 A B 4 5 6 7 1 10 23 24 29 25 30 26 31 27 32 28 33 21 22 20 2 3 18 4 16 17 5 7 13 6 14 9 11 8 12 15 19 12 8 9 10 11...

Page 3: ...ce of ignition and airing for several minutes the room where the dispenser is located Do not shake the appliance and do not tilt more than 45 degrees This appliance is not intended for use by persons...

Page 4: ...please open doors and windows for ventilation After the function switch the compressor enters the protection state You must wait for 3 minutes before the compressor can operate normally When the compr...

Page 5: ...k is used up the water temperature reaches 50 C the cooling shall be stopped and the water can only be used after the cold storage or the high temperature water in the water tank is replaced 3 4 Stron...

Page 6: ...the ventilation function Press the wind speed key to select low wind high wind and automatic wind speed Press the swing wind key to select the upper and lower swing blades to swing or stop NOTE During...

Page 7: ...o the drain such as the water collecting container or floor drain Insert the power plug into the power socket and press the on key on the control panel Press the drainage key and press the drainage ke...

Page 8: ...ick add device or on the top right of the app homepage to enter the all devices page where you can select large electrical appliances and air conditioner Match device Turn on the power supply press an...

Page 9: ...aged Knob Air inlet grille Filter screen 5 2 Filter screen cleaning Unscrew the two knobs of water inlet and water outlet from the rear side then remove the rear air inlet grille and remove the filter...

Page 10: ...not start Filter screen is dirty Compressor delay protection enabled Check whether the set temperature has been reached Clean or replace the filter screen Wait for more than 3 minutes and turn on the...

Page 11: ...or de utilizare la fiecare 3 6 luni folosi i o solu ie detartrant adecvat Nu folosi i aparatul n alt scop dec t pentru cel care este destinat Aparatul este destinat doar utiliz rii n scopuri casnice E...

Page 12: ...zul n care l r sturna i nu porni i aparatul imediat a tepta i o perioad de timp p n c nd apa din rezervor se evapor complet i apoi porni i aparatul 2 PREZENTARE PAGINA 2 Grilaj ie ire aer Admisie Intr...

Page 13: ...ervor este epuizat temperatura apei a atins 50 C procesul de R CIRE se opre te i apa se poate refolosi numai dup ce trece prin modul stocare rece cold storage sau apa cald din rezervor este nlocuit cu...

Page 14: ...cta func ia de ventila ie Ap sa i tasta wind speed vitez aer pentru a selecta vitez sc zu vitez mare i vitez automat a aerului Ap sa i tasta swing wind pentru a selecta starea lamelor basculante super...

Page 15: ...de colectare a apei chiuvet sau sifonul podelei Introduce i cordonul de alimentare n priza de curent i ap sa i tasta de pornire power supply de pe panoul de control Ap sa i tasta drainage i ine i acea...

Page 16: ...ctrice inclusiv aparatul de aer condi ionat Modalitate de operare Porni i aparatul ap s nd i men in nd ap sat tasta de pornire Power supply a aparatului timp de 10 secunde indicatorul luminos WI FI va...

Page 17: ...aj intrare aer Filtru 5 2 Cur area grilajului filtrului De uruba i cele dou butoane de intrare ie ire a apei din spatele aparatului Scoate i grilajul de intrare a aerului din spate i scoate i filtrul...

Page 18: ...dezumidificarea i nc lzirea nu pornesc Filtrul este murdar Protec ia de nt rziere a compresorului activat Verifica i dac s a atins temperatura setat Cur a i sau nlocui i filtrul A tepta i mai mult de...

Page 19: ...t s a hangjelz snek megfelel en csatlakoztassa a g pet a csapv zhez a k l n ll v zbevezet vel Lassan mozd tja az tk z s vagy a felborul s elker l se rdek ben Ne rakja ssze a dolgokat a g p leveg bemen...

Page 20: ...kell tartani s nem szabad leengedni Felborul s eset n ne ind tsa el azonnal az ramell t st hanem helyezze be egy ideig s ind tsa el az ramell t st miut n a v z teljesen elp rolgott Kimeneti leveg r cs...

Page 21: ...i kapacit sa kimer l a v z h m rs klete el ri az 50 C ot a h t st le kell ll tani s a vizet csak a hideg t rol s vagy a magas h m rs klet v z ut n lehet felhaszn lni a tart ly cser je 3 4 Er s h t s E...

Page 22: ...z lsebess g kiv laszt s hoz A swing wind gomb megnyom s val v lassza ki a fels s az als leng lap tot a leng shez vagy meg ll shoz MEGJEGYZ S A szell z s sor n megjelen ti a t nyleges leveg bemeneti h...

Page 23: ...lefoly hoz p ld ul a v zgy jt tart lyhoz vagy a padl lefoly hoz Dugja be a h l zati csatlakoz t a h l zati aljzatba s nyomja meg a kezel panel bekapcsol gombj t Nyomja meg a drainage gombot s tartsa l...

Page 24: ...almaz s kezd lapj nak jobb fels sark ban hogy bel pjen az all devices oldalra ahol kiv laszthatja a nagy elektromos k sz l keket s a l gkondicion l t Eszk z k p ros t sa Kapcsolja be az ramell t st ta...

Page 25: ...cs Sz r k perny 5 2 A sz r k perny tiszt t sa Csavarja le a v z bemeneti s kimeneti k t gombj t a h ts oldalr l majd t vol tsa el a h ts leveg bemeneti r csot s tiszt t sc lj b lvegyeleasz r v d tah...

Page 26: ...m indul el A sz r k perny piszkos A kompresszor k sleltet s nek v delme enged lyezve van Ellen rizze hogy el rte e a be ll tott h m rs kletet Tiszt tsa meg vagy cser lje ki a sz r k perny t V rjon t b...

Page 27: ...NOTES NOTI E JEGYZETEK 27...

Page 28: ...S RA VONATKOZ AN A 2012 19 EU IR NYELVEKEN Ez a szimb lum azt jel li hogy a term ket nem szabad a h ztart si szem ttel egy tt kidobni ahogy azt a WEEE direkt va 2002 96 EC s a nemzeti t rv nyek el rj...

Reviews: