37
en
3 Structural safety regulations
3.1 General information
Chassis beams and stabilisers ensure that the scaffold tower is stable. However,
depending on the place of deployment (indoor / outdoor use), these may need to be
fitted with ballast weights.
For the ballasting, see “Parts list incl. ballasting” on page 29 (lower section of the
tables)
3.2 Attaching the ballast
Where the ballast weights are attached and how many of them are required depend
on the specific set-up and platform height of the scaffold unit.
On mobile scaffold towers with stabilisers, ballast weights with fastening clamps
(Order No. 42912) must be used. The ballast weights must be attached as close as
possible to the foot of the stabiliser or on the foot of the scaffold unit (scaffold unit
types 53099 and 53199).
3.3 Attaching the anti-twist device
To prevent the stabilisers being twisted unintentionally, they should be secured with
the anti-twist device (Order No. 42865). One end of the anti-twist device is attached
to the stabiliser, the other to the first rung.