11.8 Slave warnings overview
Slave error code
Related Master
error code
Description
Effect
Machine status
when the test is
done
Restart
procedure
Current Sensor
Low
Pump Warning
Pump chopper current sensor
feedback too low (below 0,5V)
Pump motor stopped
stby
pump request
Hw Fault Valve
Pump Warning
Problem on the EN-EVS
On/off valves stopped start-up
valve on/off request
Valve Coil Shorted Pump Warning
Shortcircuit on On/off coils
On/off valves stopped start-up, stby,
during valve
function
valve on/off request
Valve driver
shorted
Pump Warning
One or more on/off valve drivers
shorted (always ON)
On/off valves stopped start-up, stby
valve on/off request
Valve Cont driver Pump Warning
One or more on/off valve drivers
opened (not able to close, so not
able to drive the valve)
On/off valves stopped during valve
function
valve on/off request
Evp Driver Ko
Pump Warning
Evp driver open (not able to close,
so not able to drive the valve)
Evp stopped
during Evp
function
valve evp request
Pump Stby I high
Pump Warning
Pump chopper current sensor
feedback too high (above 0,8V)
Pump motor stopped
start-up, stby
pump request
Pump I=0 ever
Pump Warning
Pump current feedback is always
0A even when pump motor is
running
Pump motor stopped
pump function
pump request
motor temperature Pump Warning
Pump motor temperature high
Pump chopper
maximum current
reduced to half
continuous
waiting for trac
ALARM XXX
Slave is waiting the master
incorrect start
Pump Warning
Wrong sequence in hydraulic
function request
pump/valve stopped
continuous
to do a correct
sequence
vacc not ok
Pump Warning
Hydraulic poti (lift/lowering poti)
higher than minimum value
recorded, in stby condition
pump/Evp stopped
start-up, stby
hydraulic request
ram warning
Pump Warning
checksum ram failed
continuous
eep warning
Pump Warning
checksum eeprom failed
init
lift+lower
Pump Warning
lift+lower request
Pump motor stopped
continuous
hydraulic request
eeprom ko
Pump Warning
eeprom is not online, or the
parameters in triplicate are different
Pump motor
temperature
Pump Warning
When the parameter SET
TEMPERATURE is setted, the
temperature of the motor is >150°c
Maximum current is
halfed
continuous
high temperature
Pump Warning
When the parameter maximum
current is 100% the current is
reduced lineary from 85°c to 105°C
Pump chopper
maximum current
reduced proportionally
to T increase
continuous
reduction by
master
Pump Warning
Master requests a reduction
pump speed reduced
continuous
Page - 80/86
AEQZP0BA – COMBI AC1 - User Manual
Summary of Contents for COMBI AC1
Page 29: ...7 DRAWINGS 7 1 Mechanical drawing AEQZP0BA COMBI AC1 User Manual Page 29 86...
Page 30: ...7 2 Connection drawing 7 2 1 AmpSaab version Page 30 86 AEQZP0BA COMBI AC1 User Manual...
Page 31: ...7 2 2 AmpSeal version AEQZP0BA COMBI AC1 User Manual Page 31 86...
Page 37: ...9 3 2 Master AmpSeal version AEQZP0BA COMBI AC1 User Manual Page 37 86...
Page 38: ...9 3 3 Slave AmpSaab version Page 38 86 AEQZP0BA COMBI AC1 User Manual...
Page 39: ...9 3 4 Slave AmpSeal version AEQZP0BA COMBI AC1 User Manual Page 39 86...