9.4 Function configuration (MASTER)
9.4.1 Config menu “SET OPTIONS” functions list
To enter the CONFIG MENU’ it is necessary to push in the same time the right
side top and left side top buttons. Then roll until the SET OPTION item appears
on the hand set display. Push the ENTER button.
Opening Zapi Display
CA1S2B ZAPI 1.00
24V 350A 00000
Push ROLL UP + SET UP simultaneously to enter
CONFIG MENU
% ' %
' ' '
The Display will show : SET MODEL
CONFIG MENU
SET MODEL
Press ROLL UP or ROLL DOWN button until SET
OPTIONS menu appear.
% ' '
' ' '
The Display will show : SET OPTIONS
CONFIG MENU
SET OPTIONS
Press ENTER to go in the SET OPTIONS MENU
' % '
' ' '
The Display will show the first OPTION
HOURCOUNTER
RUNNING
Press SET UP or SET DOWN button in order to
modify the OPTION
' ' %
' ' %
The Display will show the new option
HOURCOUNTER
KEYON
Press OUT to exit the menu
' ' '
' % '
The Display will ask “ARE YOU SURE”.
ARE YOU SURE?
YES=ENTER NO=OUT
Press ENTER for YES, or OUT for No
' % '
' ' '
' ' '
' % '
The Display will show : SET OPTIONS
CONFIG MENU
SET OPTIONS
Press OUT again. Display now will show the
opening Zapi menu.
' ' '
' % '
1) TILLER
SWITCH
This option handles the input CNA#7 in AmpSaab [CNA#1 in AmpSeal]. This
input opens when the operator leaves the truck (tiller released). It is
Page - 40/86
AEQZP0BA – COMBI AC1 - User Manual
Summary of Contents for COMBI AC1
Page 29: ...7 DRAWINGS 7 1 Mechanical drawing AEQZP0BA COMBI AC1 User Manual Page 29 86...
Page 30: ...7 2 Connection drawing 7 2 1 AmpSaab version Page 30 86 AEQZP0BA COMBI AC1 User Manual...
Page 31: ...7 2 2 AmpSeal version AEQZP0BA COMBI AC1 User Manual Page 31 86...
Page 37: ...9 3 2 Master AmpSeal version AEQZP0BA COMBI AC1 User Manual Page 37 86...
Page 38: ...9 3 3 Slave AmpSaab version Page 38 86 AEQZP0BA COMBI AC1 User Manual...
Page 39: ...9 3 4 Slave AmpSeal version AEQZP0BA COMBI AC1 User Manual Page 39 86...