8) BDI ADJ START UP
Adjusts the level of the battery charge table at startup, in order to calculate the
battery charge at keyon (level 0 to 9).
9) LOAD HM FROM MDI
When set On, the HourMeter of the Controller is transferred and recorded on the
HourMeter of the MDI CAN, connected to CAN BUS network.
10) CHECK UP DONE
It can be ON/OFF. If it is ON it is possible to reset the last maintenance hour-
counter and the “CHECK UP NEEDED” warning.
11) CHECK UP TYPE
It specifies the handling of the CHECK UP NEEDED warning:
-
NONE:
No CHECK UP NEENED warning
-
OPTION#1: CHECK UP NEENED warning shown on the hand set and
MDI/DISPLAY after 300 hours
-
OPTION#2: Equal to OPTION#1 but Speed reduction after 340 hours
-
OPTION#3: Equal to OPTION#2 but the truck definitively stops after 380
hours
12) MIN LIFT
This parameter stores the minimum voltage of lifting potentiometer output
connected to CNC#9. The min value acquisition is done closing the Lift SW and
bringing the potentiometer in its min output position.
13) MAX LIFT
This parameter stores the maximum voltage of lifting potentiometer output
connected to CNC#9. The max value acquisition is done closing the Lift SW
and bringing the potentiometer in its max output position.
14) MIN LOWER
%. This parameter stores the minimum voltage of lowering potentiometer output
connected to CNC#9. The min value acquisition is done closing the LOWER
SW (DI6) and bringing the potentiometer in its min output position.
15) MAX LOWER
%. This parameter stores the maximum voltage of lifting potentiometer output
connected to CNC#9. The min value acquisition is done closing the LOWER
SW (DI6) and bringing the potentiometer in its min output position.
16) MC VOLTAGE
%. This parameter stores the PWM value applied to MC coil during the first
second of the output activation. It is expressed in percentage of battery voltage.
17) MC VOLTAGE RED
%. This parameter stores the PWM value applied to MC coil after the first
second of the output activation. It is expressed in percentage of the voltage
applied during the first second (defined by the previous parameter).
18) EB VOLTAGE
%. This parameter stores the PWM value applied to EB coil during the first
second of the output activation. It is expressed in percentage of battery voltage.
Summary of Contents for ACEX
Page 27: ...AFCZP0BC COMBIACX ACEX User Manual Page 27 81 8 DRAWINGS 8 1 Mechanical drawing COMBIACX...
Page 28: ...Page 28 81 AFCZP0BC COMBIACX ACEX User Manual 8 2 Mechanical drawing ACEX...
Page 29: ...AFCZP0BC COMBIACX ACEX User Manual Page 29 81 8 3 Connection drawing COMBIACX...
Page 30: ...Page 30 81 AFCZP0BC COMBIACX ACEX User Manual 8 4 Connection drawing ACEX...