If you cannot find a solution to the problem
yourself, contact your dealer or the service cen-
tre.
The necessary data for the service centre is on
the rating plate. The rating plate is on the front
frame of the appliance cavity.
We recommend that you write the data here:
Model (MOD.)
.........................................
Product number (PNC)
.........................................
Serial number (S.N.)
.........................................
Installation
Warning!
Refer to the Safety chapters.
Important!
The built-in unit must meet the
stability requirements of DIN 68930.
The oven is designed to be connected to 230 -
240V ~ (50Hz) electricity supply.
The oven has an easily accessible terminal
block which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
Caution!
This oven must be earthed!
The cable used to connect the oven to the elec-
trical supply must comply to the specifications
given below.
For UK use only
Connection via
Min. size Cable/flex
Cable/flex type
Fuse
Cooker Control Circuit
2,5 mm²
PVC / PVC twin and
earth
min: 15 A
max: 20 A
It is necessary that you install a double pole
switch between the oven and the electricity
supply (mains), with a minimum gap of 3 mm
between the switch contacts and of a type suit-
able for the required load in compliance with the
current regulations.
The switch must not break the yellow and green
earth cable at any point.
Important!
After installation and connecting,
the cable must be placed so that it cannot at
any point reach a temperature of more than
50°C above the ambient temperature.
Before the oven is connected, check that the
main fuse and the domestic installation can
support the load; and that the power supply is
properly earthed.
The manufacturer declines any responsi-
bility should these safety measures not be
carried out.
29