16

GB

MAINTENANCE

Constant maintenance guarantees proper operation and long-term reliability. Particular
attention should be paid to the metal grease filters and,for recirculation hoods only,to the
activated  charcoal  filters.The  appliance  is  equipped  with  a  system  that  indicates
automatically when it is time to carry out maintenance operations.

Metal  grease  filters

• Cleaning

These  filters  must  be  washed  when  LED
Motor 

T2

 starts to flash,or at the most once

every 2 months,using a normal household
detergent; their compact size also enables
them to be washed in a dishwasher.

• Replacement

Remove the filters one at a time, pushing
the handle towards the rear of the hood 

(fig.

10)

. When replacing, ensure that the handle

faces outwards.

• Enabling  the  alarm  signal

The hood is already set up to trigger an alarm indicating saturation of the metal grease
filters,so this function does not need to be enabled.

• Resetting  the  alarm  signal

To turn the alarm signal off,proceed as follows:

Turn

 off the Lights 

T1

 and the Suction Motor 

T2

;

Press

 the Speed 

T4

 for at least 3 seconds,until the Leds flash in confirmation. In any

case the saturated filters alarm will only come into operation when the suction motor is
turned on.

ATTENTION - There could be a possible fire hazard if the filters are not replaced
according to these instructions.

Active  carbon  filter

• Operation

The activated charcoal filter is only fitted in recirculation type hoods.It will retain odours
until  it  becomes  saturated.It  cannot  be  washed  or  regenerated,and  must  be  replaced
when  the  Intensive  Speed  LED 

T5

  starts  to  flash,or  at  least  once  every  4  months  of

use.Attention:in recirculation type hoods the 

T2

 Motor LED may start to flash as well as

the Speed + 

T4

 LED.This indicates that as well as replacing the activated charcoal filter,it

is also necessary to perform maintenance operations on the metal grease filters (see
paragraph 

Metal grease Filter

).

Fig. 10

Summary of Contents for ZHC 929 X

Page 1: ...ap ZHC 929 X MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE HANDBOOK MANUEL D INSTRUCTIONS POUR L INSTALLATION L EMPLOI ET L ENTRETIEN HANDBUCH FÜR INSTALLATION BEDIENUNG UND WARTUNG INSTRUCTIES VOOR MONTAGE GEBRUIK EN ONDERHOUD ...

Page 2: ...east 65 cm above a cooking appliance Never do flambé cooking under this cooker hood Never leave frying pans unattended during use as overheated fats and oils may catch fire If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type If other types of flue or appliance are fitted ensure...

Page 3: ...st the wall aligning it with the vertical line at a distance X measured as shown in fig 2 equal to the height of the upper chimney element S supplied with the hood The position X may vary according to the various sizes of upper chimney element available d Mark the centres of the keyholes in the bracket on the wall Drilling fixing holes item 1 a Mark a point on the vertical line at a distance from ...

Page 4: ...umination motor and speed work properly Ducting or Recirculation fitting Ducting fitting The hood can be ducted to the outside using either rigid or flexible ducting Ø 120 or 150 mm the choice of which is left to the installer When 120 mm ducting is to be used it will be necessary to install the reduction flange item A on the air outlet fig 5 Cut the additional spigot P in correspondence with outl...

Page 5: ... the venting grilles until after the chimney has been installed Fitting the telescopic chimney To fit the upper section S first expand the two side pieces slightly hook them behind the brackets 2 and close them together again until they touch Fix the upper section S to the brackets 2 using four of the screws provided in the bag of accessories fig 7 Fit the lower section I as above between the uppe...

Page 6: ...tended Always ensure that the flame is kept at the correct intensity to prevent the flame from licking round from the bottom of the pan this will save energy and will avoid a dangerous concentration of heat Always ensure that the appliance is used in accordance with the manufacturer s instructions for the removal of contaminated air and odours during cooking Instruction for Use Control panel fig 9...

Page 7: ...this function does not need to be enabled Resetting the alarm signal To turn the alarm signal off proceed as follows Turn off the Lights T1 and the Suction Motor T2 Press the Speed T4 for at least 3 seconds until the Leds flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on ATTENTION There could be a possible fire hazard if...

Page 8: ...4 for at least 3 seconds until the Leds flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on ATTENTION There could be a possible fire hazard if the filters are not replaced according to these instructions Lighting Version with halogen spotlights 90 cm model two 20W halogen spotlights To replace fig 12 Remove the two screws ...

Page 9: ...conforme à la norme européenne sur la basse tension C E E 73 23 relative à la sécurité électrique et aux normes européennes C E E 89 336 relative à la compatibilité électromagnétique et C E E 93 68 relative au marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektromagnetischen Verträgl...