15
GB
INSTALLATION
Wall drilling and bracket fixing
Wall marking:
• Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of
the area in which the hood will be installed.
• Draw a horizontal line at:
955 mm above the hob for installation without the back panel,
a 955mm above the surface on which the pack panel rests
,
for installation with the back panel.
• Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the
centre (notch) with the vertical reference line.
• Mark the wall at the centres of the holes in the bracket.
•
Place bracket
7.2.1
on the wall as shown at X mm below the first bracket (
X
= height of the upper
chimney section supplied), aligning the centre (notch) with the vertical line
.
• Mark the wall at the centres of the holes in the bracket.
• Mark a reference point on the horizontal reference line as indicated, 116 mm from the vertical
reference line.
• Repeat this operation on the other side.
• Drill ø 8 mm holes at all the centre points marked.
• Insert the wall plugs 11 in the holes.
• Fix the brackets using the 12a (4,2 x 44,4) screws supplied.
• Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap of 5-6
mm between the wall and the head of the screw.
955
X
116
1÷2
116
955 min.
7.2.1
11
12a