background image

Quest’apparecchio é conforme alla norma europea sulla bassa tensione C.E.E. 73/23 relativa
alla sicurezza elettrica e alle norme europee: C.E.E. 89/336 relativa alla compatibilità elettro-
magnetica e C.E.E. 93/68 relativa alla marcatura CE.

This appliance complies with European regulations on low voltages, EEC Directive 73/23 on
electrical  safety,  and  with  the  following  European  regulations:  EEC  Directive  89/336  on
electromagnetic compatibility and EEC Directive 93/68 on EC marking.

Cet équipement est conforme à la norme européenne sur la basse tension C.E.E. 73/23 relati-
ve à la sécurité électrique et aux normes européennes: C.E.E. 89/336 relative à la compatibilité
électromagnétique et C.E.E. 93/68 relative au marquage CE.

Dieses  Gerät  entspricht  den  europäischen  Niederspannungsrichtlinien  73/23/EWG  zur
elektrischen Sicherheit, den europäischen Richtlinien 89/336/EWG zur elektromagnetischen
Verträglichkeit und den Richtlinien 93/68/EWG zur CE-Kennzeichnung

Dit apparaat voldoet aan de Europese Laagspanningsrichtlijn 72/23/EEG inzake de elektrische
veiligheid en aan de Europese normen 89/336/EEG inzake de elektromagnetische compatibiliteit
en 93/68/EEG inzake de CE-markering.

436000287  01  020115

Summary of Contents for ZHC 927

Page 1: ...kap ZHC 927 MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE HANDBOOK MANUEL D INSTRUCTIONS POUR L INSTALLATION L EMPLOI ET L ENTRETIEN HANDBUCH FÜR INSTALLATION BEDIENUNG UND WARTUNG INSTRUCTIES VOOR MONTAGE GEBRUIK EN ONDERHOUD ...

Page 2: ...ations contained in this Instruction Manual your appliance will give you constant high performance and will remain efficient for many years to come CONTENTS RECOMMENDATIONS AND SUGGESTIONS 13 CHARACTERISTICS 14 INSTALLATION 15 USE 19 MAINTENANCE 20 ...

Page 3: ...f aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never leave high nak...

Page 4: ...9 1 Reducer Flange ø 150 120 mm 14 1 Hood Body Air Outlet Extension Piece consisting of two Half Shells 14 1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 6 5 Q ty Documentation 1 Instruction Manual 1 Warranty 300 500 265 898 68 740 740 min 950 ma...

Page 5: ...all at the centres of the holes in the bracket Place bracket 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point on the horizontal reference line as indicated 116 mm from the vertical reference line Repeat this operat...

Page 6: ...l on the base inserting the lower plate between the upper surface and the wall centring it on the vertical reference line Mark the centres of the two holes in the upper plate Drill ø 8 mm holes at all the centre points marked Insert the wall plugs 11 in the holes Position the top Profile 20 so that it rests against the top edge of the Back panel making sure that the screw holes coincide Fix the Ba...

Page 7: ...hood body extension piece 14 Push fit the assembled hood body extension piece14 onto the air outlet Push fit connection 15 onto the hood body extension piece 14 Insert the connection extension pieces laterally 14 1 in connection 15 Make sure that the outlet of the extension pieces 14 1 is horizontally and vertically aligned with the chimney outlets If this is not the case adjust the position by ei...

Page 8: ...e two sides of the flue and hook them between the upper flue and the wall making sure that they are well seated Fixthelowerpartlaterallytothehoodbodyusing the 2 screws 12c 2 9 x 6 5 supplied On the recirculation version fit the directional grids 8a 8b in their housings making sure that the directional symbols are towards the top and front of the hood Also make sure that they are correctly inserted...

Page 9: ...ned off V5 Intensive speed Maximum speed used to eliminate the highest levels of cooking vapour emission Returns to Optimum speed automatically after it has been in operation for 15 minutes Intensive speed can also be turned off manually by pressing button V4 T Delayed shutdown This device allows any residual odours to be removed without having to wait and turn the appliance off as the Motor and L...

Page 10: ... the group and pulling down at the same time Wash the filters taking care not to bend them Allow them to dry before refitting When refitting the filters make sure that the handle is visible on the outside This filter is not washable and cannot be regener ated and must be replaced when led S5 starts to flash or at least once every four months of opera tion TheAlarmisonlysignalledwhentheRecircu lati...

Page 11: ...e Lighting support and pull it out of from the Hood Extract the Lamp from the Support Replace with another of the same type making sure that the two pins are properly inserted in the lamp holder socket holes Replace the Support fixing it in place with the two Screws removed as above ...

Page 12: ...conforme à la norme européenne sur la basse tension C E E 73 23 relati ve à la sécurité électrique et aux normes européennes C E E 89 336 relative à la compatibilité électromagnétique et C E E 93 68 relative au marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektromagnetischen Verträg...

Reviews: