background image

12

b) Pilot drill the wall using an 8 mm drill and fix the splashback using the 8 mm rawl plugs
and screws supplied.
c) If the fixing holes in the bottom of the splashback are not to be used to secure the
splashback to the wall the installer should ensure that the bottom edge is tucked down behind
the rear of the worktop.

4.2 - Fixing the canopy hood (fig. 3)

1 - Adjust the two screws 

V

 (on the canopy connection points) to approximately half way.

2 - Hook the rear of the canopy to the wall bracket 

1

, after anchoring the latter to the wall.

3 - Turn the screws 

V

 to adjust the canopy vertically and level it horizontally

.

4 - Fit and lock the central fixing screw 

V1

 (provided) to lock the canopy in place.

4.3 - Electrical connection and working test

1 - The safety measures 3.2, 3.3 and 3.4 of paragrapf 3 are to be strictly observed.
2 - Once the electrical connection has been completed, check that worktop illumination, motor

and speed work properly.

4.4 - Ducting or Recirculation fitting

1 - Ducting fitting

a) The cooker hood can be ducted to the outside using either rigid or flexible fire retardant
ducting of 120 or 150 mm. The choice is left to the installer. When 120 mm ducting is to be
used it will be necessary to install the reduction flange item 

A

 on the air outlet 

fig. 4

.

b) The installer should provide suitable ducting and sealing material for the installation. The
cooker hood can also be ducted to the outside through one of the rectangular openings
located in either side of the lower section of the chimney stack. In this case the deflector (item

D

) should be fitted into the spigot (item 

R

) to close the aperture which is not used 

(fig. 5)

.

c) If the hood is provided with the charcoal filters fitted, the filters should be removed (see
paragraph 3.3 2 part 2

a

).

2 - Recirculation fitting

a) The filtered air is returned to the room through the two side grilles on U-shaped lower
section 

I

, which are either formed in the metal itself (bottom position 

fig. 6

), or as a plastic

insert, and have two different heights to deal with different needs (bottom position 

fig. 6

, top

position 

fig. 7

).

b) Lower position 

(fig. 6)

: fit the recirculation spigot item 

R

 into the round outlet on top of

the canopy while pressing down on the spigot until it snaps into position.
c) Upper position 

(fig. 7)

: fit the additional spigot, item 

P, 

into the round outlet on top of the

canopy while pressing down on the spigot until it snaps into position. Then fit the
recirculation spigot 

R

 into the top of the spigot , item 

P

, and install the charcoal filters inside

the canopy as instructed in paragraph 3.3 2 part 2

a

).

d)Chimney hood with grilles. 

Nota: 

The two venting grilles must not be fitted into the

chimney stack until the chimney stack has been installed onto the wall above the canopy.

4.5 - Fitting the telescopic chimney stack (fig. 8)

a) Fit the two plastic supports provided to the top part of the hood.
b) To fit the upper section item 

S

 first expand the chimney slightly to allow it to fit over the wall

brackets (item 

2 fig. 1

) and then secure the upper section using the 4 screws supplied.

c) The lower section item 

I

 of the chimney stack should be fitted between the lower bracket 

2

and the wall. Fix the U-shaped section to the plastic supports, using two of the screws provided
in the bag of accessories.

Summary of Contents for ZHC 615

Page 1: ...p ZHC 615 915 MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE HANDBOOK MANUEL D INSTRUCTIONS POUR L INSTALLATION L EMPLOI ET L ENTRETIEN HANDBUCH FÜR INSTALLATION BEDIENUNG UND WARTUNG INSTRUCTIES VOOR MONTAGE GEBRUIK EN ONDERHOUD ...

Page 2: ...a sintetica 9 3 3 Filtro al carbone attivo 9 3 4 Illuminazione 9 3 5 Pulizia 9 Part 1a INSTALLATION INSTRUCTIONS 10 1 GENERAL INFORMATION 10 2 COMPONENTS 10 3 SAFETY WARNINGS 10 4 INSTALLATION 11 4 1 Fixing the wall brackets and splashback 11 4 2 Fixing the canopy hood fig 3 12 4 3 Electrical connection and working test 12 4 4 Ducting or Recirculation fitting 12 4 5 Fitting the telescopic chimney ...

Page 3: ...actif 20 3 4 Eclairage 20 3 4 Nettoyage 20 Teil 1 MONTAGEHINWEISE 21 1 ALLGEMEINES 21 2 BAUELEMENTE 21 3 SICHERHEITSHINWEISE 21 4 MONTAGE DES GERÄTES 22 4 1 Anbringung der Haltebügel und der Rückwand Abb 2 22 4 2 Montage des Haubenkörpers Abb 3 23 4 3 Elektrischer Anschluß und Funktionskontrolle 23 4 4 Anschluß Abluft oder Umluftbetrieb 23 4 5 Anbringung des teleskopierbaren Kamines Abb 8 24 Teil ...

Page 4: ... 4 4 Afzuigende of filterende aansluiting 29 4 5 Montage van de telescoopschoorsteen afb 8 29 2e deel INSTRUCTIES VOOR HET GEBRUIK EN ONDERHOUD 30 1 VEILIGHEIDSMAATREGELEN 30 2 GEBRUIK 30 3 ONDERHOUD 30 3 1 Metalen antivet filter 30 3 2 Filters van synthetische vezels 31 3 3 Aktief koolfilter 31 3 4 Verlichting 31 3 5 Reiniging 32 33 33 33 34 34 35 35 35 36 36 37 37 37 38 38 38 39 ...

Page 5: ...1 deflector D special versions only 2 7 n 1 additional recirculation spigot P special versions only see paragraph 4 4 2 part 1a 2 8 n 1 plastic bag containing n 1 wall brackets 1 to fix the canopy hood n 2 wall brackets 2 to fix the chimney rawl plugs screws and documentation 2 9 n 1 splashback B optional 3 SAFETY WARNINGS 3 1 When used in the extraction mode the cooker hood ducting must not be co...

Page 6: ... Note ensure that the wall bracket I is levelled The hood can be aligned or adjusted in height by rotating the adjustment screws see below b Mark on the wall the centres of the two keyholes of the bracket 3 Fixing the wall brackets item 2 a Place one of the two brackets item 2 fig 1 15 mm from the ceiling or from a horizontal line drawn between the top of the adjoining wall cabinets ensuring that ...

Page 7: ...he deflector item D should be fitted into the spigot item R to close the aperture which is not used fig 5 c If the hood is provided with the charcoal filters fitted the filters should be removed see paragraph 3 3 2 part 2a 2 Recirculation fitting a The filtered air is returned to the room through the two side grilles on U shaped lower section I which are either formed in the metal itself bottom po...

Page 8: ...e that the flame is kept at the correct intensity to prevent the flame from licking round from the bottom of the pan this will save energy and will avoid a dangerous concentration of heat 1 4 Always ensure that the appliance is used in accordance with the manufacturer s instructions for the removal of contaminated air and odours during cooking 2 OPERATION 1 Switch control panel fig 10 The cooker h...

Page 9: ...ches towards the rear wall which will allow the grille panel to open and hinge downward from the rear To remove the metal grille panel slide the right hand edge forward until the hinge pin comes away from the recess in the side casing as illustrated in fig 13b The filter is easily removed from the grille by pushing the wire clips to one side and removing as illustrated in fig 13c Replace the filte...

Page 10: ...ghts beside the control panel these can be replaced simply by removing the metal grease filters 2 Halogen lamps a Remove the metal lamp support in the same way as the glass diffuser fig 16 b Remove the halogen lamp with another of the same type 12V 20W fig 17 When reassembling take care that the two pins are correctly inserted in the lamp holder 3 5 Cleaning When cleaning the hood Never use a wet ...

Page 11: ...40 b a 2 1 2 1 243_A02 X 115 140 d 915 min 650 min 265 40 X 115 140 d H 265 40 H B B 1 2 ...

Page 12: ...41 3 4 5 ...

Page 13: ...42 222 6 7 ...

Page 14: ...43 10 9 8 ...

Page 15: ...44 11 12 ...

Page 16: ...45 13 a c b ...

Page 17: ...46 14 15 ...

Page 18: ...47 16 17 ...

Reviews: