17
Conversion from Natural to LPG Gas
IMPORTANT
The replacement/conversion of the gas hob
should only be undertaken by qualified
personnel.
It is important to note that this model is designed for use
with natural gas at a feeding pressure of 20 mbar but
can be converted for use with LPG providing the correct
injectors are fitted. The gas rate is adjusted to suit.
The oven burner does not need any primary
air regulation.
Replacement of gas oven
burner nozzle
To replace the gas oven nozzle, follow this procedure:
1.
Remove the bottom plate of the oven cavity (“A”);
2.
Undo the two fixing screws (“C”) which keep the
oven gas burner in place
3.
Gently slide the oven gas burner off the injector
support (“D”) and slowly move it to the left hand
side, taking care not to cause stress to the spark
candle connection wire (“E”) and the thermocouple
(“F”) conductor;
3.
With a socket spanner 7 unscrew and remove the
gas burner injector (“D”), and replace it with the
required one (see Table on this page);
4.
Reassemble the burner following the same procedu-
re backwards.
5.
Replace the Gas Type Sticker (it is located near the
gas connection ramp) with the one relevant to the
new gas type which is supplied with the injector kit.
GAS
INJECTOR
NOMINAL
NOMINAL GAS
REDUCED
BY-PASS
NOMINAL
TYPE
MARK
GAS
FLOW IN
GAS
NEEDLE
GAS
1/100 mm
POWER
POWER
(1/100 mm)
PRESSURE
(kW)
m
3
/h
g/h
(kW)
(mbar)
114
2,5
0,265
-
1,0
Reg.
20
78
2,3
-
177
1,0
52
28-30 / 37
124
2,5
0,265
-
1,0
Reg.
13
Oven Gas Burner Data
Natural Gas
(G20)
LPG
(G30/G31)
Natural Gas
(G20)
Summary of Contents for ZGT 1
Page 2: ...2 ...
Page 19: ...19 ...
Page 20: ...Grafiche MDM Forlì 35692 5401 AM 04 06 www electrolux com ...