GAS BURNERS FOR NATURAL GAS G20 20 MBAR
BURNER
NORMAL POWER kW
MINIMUM POWER kW
INJECTOR MARK
Rapid
3,0
0,75
119
Semi-rapid
2,0
0,45
96
Auxiliary
1,0
0,33
70
GAS BURNERS FOR LPG G30/G31 28-30/37 MBAR
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30 mbar
G31 37 mbar
Rapid
2,8
0,75
86
204
200
Semi-rapid
2,0
0,45
71
145
143
Auxiliary
1,0
0,33
50
73
71
ELECTRIC COOKING ZONES SPECIFICATION
Cooking zone
Nominal Power (Max heat setting)
[W]
Cooking zone diameter [mm]
Left rear
1500
145
For optimal cooking results use cookware not larger
than the diameter of the cooking zone.
ENERGY EFFICIENCY
PRODUCT INFORMATION ACCORDING TO EU 66/2014
Model identification
ZGM62444XA
Type of hob
Built-in hob
Number of electric cooking zones
1
Heating technology per electric cooking
zone
Solid Hot Plate
Diameter of circular electric cooking
zones (Ø)
Left rear
14.5 cm
Energy consumption per cooking zone
(EC electric cooking)
Left rear
199.9 Wh / kg
Number of gas burners
3