Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
REDUCED POWER kW
INJECTOR MARK
1/100 mm
Rapid
3,0
0,72 / 0,75
119
Semi-rapid
2,0 / 1,9
0,43 / 0,45
96
Auxiliary
1,0
0,35
70
Oven
2,7
0,90
120
Gas burners for LPG G30 50 mbar
BURNER
NORMAL
POWER kW
REDUCED POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid
3,0
0,72
77
218,14
Semi-rapid
2,0
0,43
60
145,43
Auxiliary
1,0
0,35
43
72,71
Oven
2,5
0,90
63
181,78
Grill
2,0
-
60
145,43
Gas burners for LPG G31 50 mbar
BURNER
NORMAL
POWER kW
REDUCED POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid
3,0 / 2,6
1)
0,72 / 0,63
1)
77
214,24 / 185,68
1)
Semi-rapid
1,7
0,4
60
121,40
Auxiliary
0,85
0,31
43
60,70
Oven
2,15
0,78
63
153,54
1) Type of bypass (Copreci / BSI) depends on model.
Gas Connection
Before installation take off the sticker, which is
on the gas pipe at the back of the appliance.
Clean the pipe from any glue remains.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible metallic
pipes, make sure they do not come in touch
with mobile parts and they are not squeezed.
CAUTION!
When you install and connect the
appliance, obey the directives:
• SVGW- Gas principles G1: Gas
installation
• EKAS- Form. 1942: Liquid gas
directive, Part 2
• Cantonal instances regulations
(e.g. fire safety regulators)
Install and connect the appliance in
accordance to the directives.
www.zanussi.com