The appliance is designed to be connected to 230 V
monophase electricity supply.

The connection must be carried out in compliance with
the laws and regulations in force.

Before the appliance is connected:

1) check that the main fuse and the domestic installation

can support the load (see the rating label);

2) check that the power supply is properly earthed in

compliance with the current rules;

3) check the socket or the double pole switch used for

the electrical connection can be easily reached with
the appliance built in the forniture unit.

The appliance is supplied with a connection cable. This
has to be provided with a proper plug, able to support the
load marked on the identification plate. To connect the
plug to the cable, follow the recommendation given in
Fig. 5. The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system,
it is necessary that you install a double pole switch
between the appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch contacts and
of a type suitable for the required load in compliance
with the current rules.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 90 

°

C higher

than the room temperature.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.

REPLACEMENT OF THE VOLTAGE CABLE

The connection of the voltage cable to the appliance's
terminal block is of type "Y". This means that its
replacement requires the specific equipment of a
technician.
In this case, only cable type H05V

2

V

2

-F T90 must be

used. The cable section must be suitable to the voltage
and the working temperature.
The yellow/green earth wire must be approximately 2
cm. longer than the phase wires (Fig. 5).

To open the terminal block and reach the terminals,
proceed as follows:

insert the point of a screwdriver into the visible
protrunding part of the terminal block;

exert a light pressure and lift (Fig. 6)

5. Electrical Connection

Fig. 5

Fig. 6

FO 0073

FO 0257

Neutral

Earth (yellow/green)

Summary of Contents for ZAF2

Page 1: ...MODE D EMPLOI GEBRUIKSAANWIJZING BEDIENUNGSANWEISUNGEN INSTRUCTIONS FOR USE TABLES DE CUISSON KOOKPLATEN KOCHMULDEN HOBS ZAF 2 ...

Page 2: ...quent modifications During Operation About Installation Cleaning and Manteinance It is mandatory that all operations required for the installationarecarriedoutbyaqualifiedorcompetent person in accordance with existing rules and regulations Disconnect the appliance from the electrical supply before carrying out any cleaning or manteinance work Ensure a good ventilation around the appliance A poor a...

Page 3: ...t out before taking the pans off the burner USING THE HOB CORRECTLY To ensure maximum burner efficiency it is strongly recommended that you use only pots and pans with a bottom fitting the size of the burner used so that flame will not spread beyond the bottom of the vessel see the table beside It is also advisable as soon as a liquid starts boiling to turn down the flame so that it will barely ke...

Page 4: ...th a soft cloth The pan supports are dishwasher proof If the marks are particularly difficult to remove use common non abrasive cleaners or specific products Never use steel wool pads or acids In models provided with electric ignition this feature is obtained through a ceramic candle and a metal electrode fig 1 lett C Keep these components well clean to avoid difficult lighting and check that the ...

Page 5: ...use by these two types of gas Before fitting the appliance ensure that the installation hasthecorrect voltagefortheappliance Atfullcapacity the drop in pressure must not exceed 5 Such a drop in pressure is caused by the following parameters maximum capacity of meter diameter and lenght of the tube in front and behind the meter section of transit of variuos tubes positioned on the circuit diameter ...

Page 6: ...ance and the electricity supply with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current rules The connection cable has to be placed in order that in each part it cannot reach a temperature 90 C higher than the room temperature The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnect...

Page 7: ...T OF MINIMUM LEVEL To adjust the minimum level of the burners proceed as follows Light the burner Turn the knob on the minimum position Remove the knob With a thin screwdriver adjust the by pass screw seeFig 8 a IfchangingfromnaturalgastoLPG completely tighten clockwise the screw until a small regular flame is obtained Finally check the flame does not go out when quickly turning the knob from the ...

Page 8: ...ithout overlapping place the hob in the cut out taking care of its centring fix the hob with the relevant screws Fig 11 The traction of the screws is able to trace the sealing any excess of which can then be easily removed The edge of the hob forms a double labyrinth seal which provides a total guarantee against infiltration of liquids If several function are to be combined 2 burners hob fish kett...

Page 9: ...ion given in Figs 13 and 16 and must be provided with brackets to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 14 and 15 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily taken off the unit Hanging forniture units or hoods must be placed at 650 mm ...

Reviews: