Electrical connection
This machine is designed to operate on a 220-230 V,
single-phase, 50 Hz supply.
Check that your domestic electrical installation can take
the maximum load required (2.2 kW), also taking into
account any other appliances in use.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability should
this safety measure not be observed.
The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved (BS1362) fuse must
be used.
Should the plug need to be replaced for any reason,
proceed as described below.
The wires in the mains lead are coloured in accordance
with the following code:
Green and Yellow
- Earth
Blue
- Neutral
Brown
- Live
The wire coloured green and yellow must be connected
to the terminal marked with the letter «E» or by the
earth symbol
or coloured green and yellow.
The wire coloured blue must be connected to the
terminal «N» or coloured black.
The wire coloured brown must be connected to the
terminal marked «L» or coloured red.
Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
WARNING:
A cut off plug inserted into a 13 amp socket is
a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely.
GREEN & YELLOW
BROWN
CORD CLAMP
BLUE
13
A
P1041
E
N
L