45
Mod. CRONOS rev 01
Instructions for use
translated from the original text
EN
fig. 25 control panel - initial pellet loading
4.10 BOILER STATUS
Displays the instantaneous status of the boiler by showing
the status of the various devices connected to it. Various pag-
es are available and displayed in sequence. The following also
appear on the display: Timer 1 (A), Time-out (B), Status (C),
Alarm delay (D), Operating status (E), Flue gas Temp. (F), Flue
gas Flue gas extraction (G), Instant power (I), Alarm in pro-
gress (N).
fig. 26 control panel - stove status display
4.11 IGNITION
To switch the product on, press the key (1) for a few seconds.
The display shows when the snow has started (see fig. 28)
fig. 27 control panel - ignition
4.12 START-UP PHASE
The product performs the start-up phases in sequence as de-
fined by the parameters managing levels and times.
1
A
C
B
A
B
E
D
C
F
G
I
N
1
4.13 FAILED IGNITION
When a time preset by the manufacturer has elapsed and the
flue gas temperature has not reached the minimum value,
also preset by the manufacturer, the product goes into alarm
status (see table 7 problems/causes/remedies in chap. 7.3).
4.14 STANDARD OPERATION
Upon successfully completing the start-up phase, the stove
switches to the "operating" mode that represents standard op-
eration.
fig. 28 control panel - operating condition
4.15 CHANGING THE ROOM TEMPERATURE
SETTING
To change the room temperature, just act on the keys (1) and
(2). The display shows the current status of the temperature
setting, fig. 29.
fig. 29 control panel - room temperature change
4.16 USING THE EXTERNAL THERMOSTAT/
CHRONOTHERMOSTAT
It is possible to connect an external thermostat to the boiler
for remote management of some functions.
• external thermostat: set a temperature of 7°C.
• external chronothermostat: set temperature of 7°C and
from the menu “
03 Set chrono -> 01 enable chrono
” disable
the chrono function (
off
).
The stove is enabled when it is on and the contact
is closed. The external thermostat must be con-
nected by the Authorised Assistance Centre.
4.17 ROOM TEMPERATURE REACHES THE SET
TEMPERATURE
When the room temperature or the flue gas temperature have
reached the set value, the heat output is automatically
brought to the minimum value “MODULATION" condition, see
fig. 30.
fig. 30 control panel - set temperature modulation
1
2
Summary of Contents for CRONOS
Page 2: ......
Page 26: ...26 Mod CRONOS rev 01 Tradu o do texto original Solu o de problemas PT...
Page 52: ...52 Mod CRONOS rev 01 Troubleshooting translated from the original text EN...
Page 78: ...78 Mod CRONOS rev 01 Solution probl mes Traduction des instructions originales FR...
Page 84: ...84 Mod CRONOS rev 01...
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ...Mod CRONOS rev 01...