160
Electronics and wiring
5.6 Managed Devices
M8, M9 e M10 Evaporator Fans
Managed by Relay:
K8, K9 and K10
Protected by Fuses:
F8,F9,F10,F11,F12,F13
Ports:
J13, J14, J15, J16, J17 and J18
Digital Output label:
Evaporator Fans
5.6.3.2.1
Flat Evp. Motorfans
Specifications:
Supply voltage DC
12V
Power Absorption
220W
Diameter 385mm
(15”)
Air Flow:
4280 m
3
/h (2530 ft
3
/min)
Enclosure rating IP67
5.6.3.2.2
Cubic Evp. Fan Motor Specifications:
Supply voltage DC
12V
Power Absorption
70W
Speed
2200rpm
Diameter 250mm
(9.8”)
Air Flow:
1200 m3/h (760 ft3/min)
Enclosure rating IP20
Engine Devices
PN Fuel Pump
Functions:
Supply voltage DC
12V
Power Absorption
18W
Flow Rate
2 l/min (33GPH)
Operating Temp. Range
−40 to 80 [°C] (−40 to 180[°F ])
Connections:
Port-Pin by Wire
J12
− 4th
16
J12
− 9th
NE129
Specifications
:
Supply voltage DC
12V
Power Absorption
20W
Enclosure rating IP65
Managed by Relay:
KFP
J 20 – 1st
Protected by Fuse:
FA3
Summary of Contents for un0 060
Page 1: ...0MAN295 USA WORKSHOPMANUAL un0...
Page 4: ......
Page 15: ......
Page 16: ......
Page 17: ...Section1 Generalinformation...
Page 19: ......
Page 30: ......
Page 31: ...Section2 Descriptionoftheunit...
Page 33: ......
Page 45: ...34 Description of the unit 2 2 Evaporating section...
Page 46: ......
Page 47: ...Section3 CoolingCircuit...
Page 94: ......
Page 95: ...Section4 DieselEngine...
Page 97: ......
Page 130: ......
Page 131: ...Section5 ElectronicsandWirings...
Page 135: ......
Page 146: ...135 5 2 Electronic Boards Electronics and wiring 5 2 Electronic Boards CPU board...
Page 150: ...139 5 2 Electronic Boards Electronics and wiring Relay Board...
Page 155: ...144 Electronics and wiring 5 2 Electronic Boards Low Voltage Wirings...
Page 156: ...145 5 2 Electronic Boards Electronics and wiring High Voltage Wirings...
Page 178: ......
Page 179: ...Section6 Alarms Troubleshooting...
Page 181: ......
Page 183: ...172 Alarms Troubleshooting 6 1 StandardAlarms A04 Low Pressure Switch...
Page 184: ...173 6 1 StandardAlarms Alarms Troubleshooting A07 Water Temperature A08 Door Microswitch...
Page 185: ...174 Alarms Troubleshooting 6 1 StandardAlarms A10 Oil Pressure...
Page 186: ...175 6 1 StandardAlarms Alarms Troubleshooting A11 High Pressure...
Page 188: ...177 6 1 StandardAlarms Alarms Troubleshooting A16 Engine Failure...
Page 189: ...178 Alarms Troubleshooting 6 1 StandardAlarms A17 Alternator Failure...
Page 190: ...179 6 1 StandardAlarms Alarms Troubleshooting A18 Water sensor error...
Page 195: ...184 Alarms Troubleshooting 6 3 Troubleshooting Unit does not start after blackout...
Page 196: ...185 6 3 Troubleshooting Alarms Troubleshooting Unit not performing...
Page 197: ......
Page 198: ......
Page 199: ...Annex1 Parameters...
Page 201: ......
Page 208: ......
Page 209: ......