66
Instructions for the installer
The instructions given below are designed
specifically for a qualified installer and
should aid him or her to perform all
installation, adjustment, and maintenance
operations with absolute precision and in
compliance with all current legislation and
regulations. We strongly recommend that
all operations for the installation of your
cooker be carryed out by Qualified
Personnel in accordance with existing rules
and regulations.
Electrical connection
Prior to making the electrical connection, make
sure that:
—
the protection fuse and the domestic wiring
system are suitable to carry the total electric
load of the oven (see rating plate);
—
your domestic wiring system has an
efficient earth connection in compliance
with rules and laws in force;
—
the wall socket or the omnipole switch used
for the electrical connection can easily be
reached after the oven is built in.
This appliance is delivered without an electric
supply cable, therefore, you will have to fit to
it a supply cable with standard plug, suitable
for the total electric load shown on the rating
plate. The plug is to be inserted into a suitable
wall socket. If you require a direct connection
to the electric network (mains), it will be
necessary to fit between the appliance and the
mains an omnipole switch, with a minimum
gap between contacts of 3 mm, suitable for
the required load and in compliance with rules
in force. The green & yellow ground wire must
not be interrupted by the switch. The supply
cable must in all cases be laid out in such a
way as to ensure that it does not reach at any
given point a temperature 50
°
C higher than
the ambient temperature.
The Manufacturer disclaims any liability in
case these accident-preventing rules are not
observed.
Suitable power supply cables are the following
types, considering the respective necessary
section of cable.
H07 RN-F
H05 RN-F
H05 RR-F
H05 VV-F
Connecting the terminal board
The appliance incorporates an easily accessible
3-pole terminal board pre-set for operation on
230V single-phase (Fig.10). The ground cable
must be connected to terminal
. After
connecting the supply cable to the terminal
board, secure it with a junction clamp.