19
Safety Relay MINOS SD1E
EN
Safety circuit
Single-channel monitoring of safe OSSD
output.
Up to PL e / SILCL 3
Position Config-Switch S1: Disabled (Right)
Fig. 15
OSSD outputs single channel
Start circuit
Monitored manual start without feedback
circuit.
Note:
Evaluation of the falling edge of the
start signal (contact opens).
Position Config-Switch S2: Manual (Left)
Fig. 16
Manual start without feedback circuit
Note:
OSSD-Output meet the requirements for
Safety-Level and fault exclusion of a short
circuit in the safety circuit according to
EN ISO 13849-2.