background image

10

INTERNAL CALLS (DISPLAY-TO-DISPLAY INTERCOM MODE)

The intercom mode allows two-way voice calls between two specific displays  
in the video entry phone system. Touch 

 on the display on standby to call another 

display in the system. If you have more than 2 displays in the video entry phone 
system, choose the display you wish to call with 

 or  . Next, touch 

  

to confirm and make the call. The user at the display being called can touch 

  

to answer the call or   to reject the call.

DISPLAY SOUND VOLUME / BRIGHTNESS / COLOUR  
/ CONTRAST / IMAGE TYPE CONTROL

Touch   or   in the monitoring, incoming call, voice call, intercom, or public 

address mode to open the sound volume menu. Next, touch 

 to open  

the Volume / Brightness / Colour / Contrast / Image Type menu. Operate  
the controls with 

 or 

.

DO NOT DISTURB MODE

You can enable or disable the DO NOT DISTURB mode in the display System 
Settings menu. Touch and hold 

 to enable or disable this mode.

DISPLAY MICROPHONE MONITORING

With the display on standby, touch and hold 

 to start listening through  

the microphone of another display in the voice entry phone system. If you have 
more than 2 displays in the video entry phone system, choose the display you wish  
to listen to by touching 

 or 

 and confirm with 

.

Note:
a) The user of the display that is listening will hear everything that the microphone  

of the display being listened to captures. The display being listened to will not 
output the sounds captured by the microphone of the display which is listening.

b) If you have more than 2 displays in the video entry phone system, verify that  

the remote listening mode is enabled in the display to which you want to listen.  
Go to System Settings and verify that Can Be Monitored is set to Enable.

Summary of Contents for VP-819B

Page 1: ...esults of damage and or accidents caused by non intended use of the product Before attempting to install this product please read and understand the entire Operating Manual to comply with the intended...

Page 2: ...nds Electrocution hazard Do not attempt to disassemble repair or alter this product on your own Risk of electrocution damage to the product and or fire Do not install a current breaker on the mains co...

Page 3: ...CTION DIAGRAM AD Audio VD Video PWR Power GND Ground DATA Data communication CCTV CCTV feed in KEY1 KEY2 Control voltage J4 J4 J4 J4 ROOM 1 ROOM 2 ROOM 3 ROOM 4 ELECTRIC CATCH 2 ELECTRIC CATCH 1 DISPL...

Page 4: ...power GND and KEY1 contacts c External power supply port J4 optional d Wiring connection diagram for the NC06 gate control module Connector P3 GND and DATA to NC06 COM NO NC to gate control AD Audio V...

Page 5: ...meras to which they are connected All displays can output the video feed of a CCTV camera connected to the entrance panel port AD Audio VD Video PWR Power GND Ground DATA Data communication CCTV CCTV...

Page 6: ...4 wideo monitory 2 kamery CCTV do ka dego monitora DRZWI 1 KAMERA1 KAMERA2 KAMERA1 KAMERA1 KAMERA1 KAMERA2 KAMERA2 KAMERA2 DRZWI 2 DRZWI 1 KAMERA1 KAMERA2 KAMERA1 KAMERA1 KAMERA1 KAMERA2 KAMERA2 KAME...

Page 7: ...onnections are correct 2 Choose a suitable location in which to install the display unit An installation height between 1 5 and 1 6 m above the ground is recommended 3 Verify that the power supply vol...

Page 8: ...entrance panel is 30 m away from the video entry phone display use YTDYw 4 x 0 5 mm2 wiring ENTRANCE PANEL ELECTRIC CATCH 1 2 3 4 1 2 3 4 RED BLUE YELLOW WHITE RED BLUE YELLOW WHITE GREEN BROWN If th...

Page 9: ...h and hold again to unmute your microphone which the display will confirm with SPEAK Operating a gate requires the NC06 gate control module in the system VIDEO FEED MONITORING With the display on stan...

Page 10: ...th or DO NOT DISTURB MODE You can enable or disable the DO NOT DISTURB mode in the display System Settings menu Touch and hold to enable or disable this mode DISPLAY MICROPHONE MONITORING With the dis...

Page 11: ...icrophones can be enabled in the System Settings 6 MONITOR UNLOCK Touch to unlock the electric catch linked to the entrance panel Touch to open the gate linked to the entrance panel 7 DEVICE ADDRESS R...

Page 12: ...peration of the goods manufactured by ZAMEL Sp z o o c damagecausedbyanymodificationsmadebytheBUYER or any third party to the sold goods or to the equipment required for the proper functioning of the...