![Zamel VP-819B Operating Manual Download Page 8](http://html2.mh-extra.com/html/zamel/vp-819b/vp-819b_operating-manual_3165569008.webp)
8
WIRING SPECIFICATIONS
The system supports two electric catch release configurations: with the open
command sent by (i) an entrance panel or (ii) a system display (the display open
command output wire must have the shield connected to earth).
If the open command is sent by an entrance panel, use this wiring specification:
• If the entrance panel is < 30 m away from the video entry phone display,
use YTDYw 4 x 0.5 mm
2
wiring.
ENTRANCE PANEL
1
2
3
4
1
2
3
4
RED
BLUE
YELLOW
WHITE
RED
BLUE
YELLOW
WHITE
GREEN
BROWN
• If the entrance panel is > 30 m away from the video entry phone display,
use YTDYw 4 x 0.5 mm
2
wiring.
ENTRANCE PANEL
ELECTRIC
CATCH
1
2
3
4
1
2
3
4
RED
BLUE
YELLOW
WHITE
RED
BLUE
YELLOW
WHITE
GREEN
BROWN
If the open command is sent by a display, use this wiring specification:
• If the entrance panel is < 30 m away from the video entry phone display,
use YTDYw 6 x 0.5 mm
2
wiring.
ENTRANCE PANEL
ELECTRIC CATCH
RED
BLUE
YELLOW
WHITE
BROWN
RED
BLUE
YELLOW
WHITE
BLACK
GREEN
• If the entrance panel is < 30 m away from the video entry phone display,
use YTDYw 6 x 0.8 mm
2
wiring.
ENTRANCE PANEL
ELECTRIC CATCH
RED
BLUE
YELLOW
WHITE
BROWN
GREEN
RED
BLUE
YELLOW
WHITE
BLACK
GREEN
DISPLAY
DISPLAY
DISPLAY
DISPLAY
ELECTRIC
CATCH
GREEN