Gate control module SBW-01
TECHNICAL DATA
24 V AC/DC
Nominal supply voltage:
Nominal frequency:
AC :Stand-by/Relay switched on: AC: 16mA/62mA
Rated power consumption:
DC :Stand-by/ Relay switched on: DC 10mA/27mA
0,45 W
Transmission:
Wi-Fi 2.4GHz b/g/n
Operating range:
Wi-Fi network operating range
Number of inputs:
2
Number of output channels:
1
Relay contact parameters:
1 x NO 5A / 250 V AC (voltage free a-contact)
Maximum output load:
5 A / 250 V AC
Number of connection terminals:
6 (cables up to 2,5 mm
2
cross-section)
Temperature operating range:
-20 to +55°C
Ingress protection rating:
IP20
Dimensions:
47,5 x 47,5 x 20 mm
Weight:
0,04 kg
Compliance with standards:
EN 60669-1, EN 60669-2-1, ETSI EN 300 328,
ETSI EN 301 489-1, EN 301 489-17
INSTALLATION NOTES:
1. Do not install the receivers in close proximity to each other (if possible, maintain a minimum
distance of 15 cm between receivers). Especially avoid installing one receiver above another.
This may cause interference with Wi-Fi communications.
2. Observe the maximum outputs load:
3. During installation, make sure that the module is not exposed to direct contact with water and
operation in a humid environment. The installation site temperature should be between -20 and
+55°C.
4. The SBW-01 module is designed for indoor installation. When installing outdoors, the unit must be
placed in an additional weatherproof box.
5. Voltage free control contacts can be connected to the inputs IN1 and IN2 of the SBW -01 receiver,
allowing detection of the gate status - open / closed.
6. Once the receiver has been installed, check its correct operation by observing whether the LED
is on.
MOUNTING
•
The SBW-01 module is designed for mounting in junction boxes. Dimensions of the hous ing allow
for both fl ush-mounted (minimum Ø60) and surface-mounted boxes.
•
The device must be connected to a single-phase power network in accordance with the applicable
standards. Installation, connection and adjustment activities should be carried out by qualifi ed
electricians who have read this manual and the functions of this device. For safety reasons, do not
install the unit without the housing or with a damaged housing.