background image

 

Technical data 

 

Nominal voltage supply:  230 VAC 

Nominal frequency:  50 / 60 Hz 

Nominal power consumption:  0,45 W 

Transmission:  Wi-Fi   

Operation range:  do 200 m in the open area 

Number of external inputs:  2 

 Cooperation with switches:   monostable (push-buttons) 

bistable (standard lighting switches without 
backlight) 

Number of output channels:  1 

Relay contact parameters:  

(voltage free NO contact) 

1 x NO 5A / 250 VAC 
 

Maximum output load:    1 x 5A / 250 V AC 

incandescent and halogen lamps 

 750 W 

 

 

 

CFL lamps 

 250 W 

 

 

 

LED lamps

 60 W 

 

Number of terminal clamps:  6 (cross-section of wires up to 2,5 mm2) 

Casing mounting: 

Ø60 

mm junction box 

Temperature operation range:  -

10 do +55 °C

 

Casing protection degree:  IP20 

Protection class:  II 

Dimensions:  47,5 x 47,5 x 20 mm 

 

Weight:  0,04 kg  

Reference standard:  PN-EN 60669, PN-EN 60950, PN-EN 61000 

PN-ETSI EN 300 220-1 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Summary of Contents for ROW-01

Page 1: ...1 ZAMEL ROW 01 FITTING INSTRUCTION MANUAL...

Page 2: ...2 Content Technical data 4 Installation remarks 5 Mounting 5 Registry 8 ROW 01 module configuration 9 Installation and configuration of SUPLA on smartphones or tablets 13...

Page 3: ...sure there is no voltage on the connection cables by means of a special measuring equipment before mounting We did our best to make the product operates properly But if you have any remarks regarding...

Page 4: ...er of output channels 1 Relay contact parameters voltage free NO contact 1 x NO 5A 250 VAC Maximum output load 1 x 5A 250 V AC incandescent and halogen lamps 750 W CFL lamps 250 W LED lamps 60 W Numbe...

Page 5: ...inputs are designed to cooperate with monostable or bistable switches By default the IN1 input operates in the monostable mode doorbells and the IN2 input in the bistable mode for standard lighting s...

Page 6: ...roper circuit Remove the switch and disconnect the wires 2 Connect the device to power supply in accordance with one of the below presented installing diagram and switch on the power supply from the m...

Page 7: ...7 Diagram no 2 includes device mounting behind a monostable switch doorbell...

Page 8: ...nt yet register now and follow the below presented steps Registration and system usage are free of charge Open https cloud supla org website and click Create an account screenshot of https cloud supla...

Page 9: ...regarding the connection and configuration of ROW 01 module Configuration ROW 01 module After the device has been switched on the software controls the settings In case the settings have not been imp...

Page 10: ...ed to Wi Fi networks and has an installed browser After a connection to the W Fi ZAMEL ROW 01 has been completed successfully you can open the browser and enter the following address http 192 168 1 in...

Page 11: ...a dev which is displayed after logging in at https cloud supla org Rewrite data from the yellow field into the red ones It means rewrite Server address into Server field Location ID into Location ID a...

Page 12: ...ction It is signalled by a flashing LED 2 flashes 1 second In case of a positive connection the device establishes a connection with SUPLA server It is signalled by a flashing LED 1 flash 1 second The...

Page 13: ...on smartphones or tablets In case of smartphones tablets with Android system operation open Google Play store next find the SUPLA application and install it In case of iPhone or iPad open AppStore nex...

Page 14: ...ata in the green form supla client which is displayed after login in at https cloud supla org Rewrite data from the green form into the red fields After entering all settings correctly the application...

Reviews: