OUTPUT MODE CONFIGURATION

AFTER POWER SUPPLY SWITCH ON

In case of ROP-21 receiver, it is possible to configure its input operation mode after power supply 

has been switched on. As a default setting, the receiver’s 

input is switched off. Possible output modes:
•  switched off (11-14 normal open),
•  switched on (11-14 normal closed),
•  previous mode - after power supply has been switched 

on, the input mode is the same as before power supply 

failure. Time mode is an exception – if power supply 

is switched off during time measurement, then after 

power supply is switched on again – the input remains in the switched off mode.

After power supply is switched on, the output operation mode is adjusted in the receiver con-

figuration tab.

REMOTE SOFTWARE UPDATE 

•  ROP-21 receiver is equipped with a built-in bootloader, which allows for a remote software 

change by means of the EXTA LIFE application. Software update is possible only in case of 

receivers paired with a controller and can be realized only by an authorised user (an administra-

tor). It is required to connect the EXTA LIFE controller to the Internet to carry out the update. 

•  The current ROP-21 software update is displayed in the “Configuration details” tab. The ‘Up-

date’ push-button is backlit, in case there is a new software version. By pressing this push–

button, information is sent to a controller, which enters the receiver into the software update 

mode. The latest software is sent to a receiver by means of a controller. If the update has been 

completed successfully, such a message is sent to a controller from a receiver and, additionally, 

itis signalled in the mobile application. The update can be carried out only by an authorised user 

(an administer).

•  If, for any reason, the software update has not completed successfully, then the receiver is 

marked as ‘a receiver with an update error’ by the controller.  This receiver does not have its 

original functionality any more. Then, if the “Configure” option for this receiver is selected by 

means of an application, there is an immediate change to the “Configuration details” screen 

with a backlit ‘Update’ field. Software update starts just after pressing this button.

.

Summary of Contents for ROP-21

Page 1: ...n switching off time Number of external inputs 2 Cooperation with push buttons monostable push buttons bistable Operating modes for external inputs only switching on only switching off bistable monost...

Page 2: ...lity The receiver has an implemented function of a re mote software update by means of the controller FUNCTIONALITY 1 The ROP 21 receiver can be simultaneously controlled by EXTA LIFE system transmitt...

Page 3: ...ied the receiver will carry out service activities for about 5 seconds it is signalled by a green STATUS LED it will flash at an interval of 1 second During this time the control of a receiver is not...

Page 4: ...ATUS LED flashes orange to signal the push buttons have been assigned correctly Bistable mode 1 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 2 In 5 sec press the b...

Page 5: ...mitter should cooperate with a receiver In case of ROP 21 the switch on switch off bistable monostable and time modes are possible 6 Choose push buttons of a transmitter that will be assigned remotely...

Page 6: ...y transmitter s push buttons from a receiver it is required that the receiver is paired with the EXTA LIFE controller To do the above the following steps must be carried out 1 Choose the Configure opt...

Page 7: ...con is assigned to the ROP 21 receiver 7 The receivers just after pairing can be controlled at once by means of application buttons The receiver s mode is signalled by a switch position and a switch i...

Page 8: ...guration change 1 Activate the application and enter the Device screen 2 Select the Configure option from the receiver s menu 3 Expand the screen and configure separately the IN1 and IN 2 input First...

Page 9: ...ed only by an authorised user an administra tor It is required to connect the EXTA LIFE controller to the Internet to carry out the update The current ROP 21 software update is displayed in the Config...

Reviews: