background image

DESCRIPTION

FEATURES

• nominal supply voltage 230 V AC,

• compatible with a controller and EXTA LIFE system transmitters,

• 1 output channel (NO dry contact),

• two-way transmission – current output mode indicated in the application,

• programmable output mode after power supply is switched on,

• 2 programmable external inputs,

• connection possibility of monostable or bistable switches,

• 4 operation modes in cooperation with transmitters (switch on / switch off, bistable, monostable, 

time),

• 2 operation modes in cooperation with a controller (switch on / switch off, time)

• independent time for radio transmitters, controllers and external input, 

• independent remote software update,

• dedicated to control any devices of <750 W power,

• mounting in Ø60 mm junction box.

Radio flush receiver ROP-21 is a final element of the EXTA LIFE system, which allows to control 

home and office devices. The output in the form of a single normally open contact gives a pos-

sibility to control low voltage (e.g. 12/24 V AC/DC) and high voltage (230 V AC) circuits. ROP-21 

is reliable also during a remote triggering of other devices – it can be used during transmission of 

control signals. The receiver can additionally be used to control electro valves in heating systems. 

Current mode of the device controlled by ROP-21 is shown in the mobile application, due to a two-

way communication between a receiver and a controller. This method of communication allows for 

parameterisation of a receiver and a remote adding of transmitters (without a physical access to a 

receiver). Frame encoding algorithm ensures control security. ROP-21, apart from the controller, 

can be simultaneously operated by the EXTA LIFE system transmitters. A larger number of transmit-

ters can be added to a receiver which, in turns, enables an independent control from several places. 

The device is designed for (surface and flush) junction box installation. The additional configured 

wired inputs increase the control functionality. The receiver has an implemented function of a re-

mote software update by means of the controller. 

FUNCTIONALITY 

1.  The ROP-21 receiver can be simultaneously controlled by:

• EXTA LIFE system transmitters (switch on / switch off, bistable, monostable, time)

• EXTA LIFE mobile application, after pairing with a controller (switch on / switch off and time 

modes)

• IN1, IN2 external inputs (operating mode depends on a switch type – see Functionality of 

inputs).

2.  Current receiver’s mode is shown in the mobile application.

3.  It is possible to assign a larger number of push-buttons of EXTA LIFE transmitters to one re-

ceiver – maximum 96 pairs (e.g. 24 transmitters in the switch on/switch off mode).  

4.  Transmitters’ push-buttons can be assigned to a receiver “locally” by means of the PROG. push-

button or „remotely” by means of the mobile application.

5.  Few transmitters can cooperate with one transmitter – it is recommended that a transmitter is 

assigned to each receiver in the switch on / switch off mode.

6.  A dimmer can be paired only with one EXTA LIFE controller. After pairing the receiver is not 

visible for other controllers.

7.  Push-buttons added to a receiver’s memory can be selectively deleted. 

8.  There is a possibility to delete simultaneously all push-buttons added to a receiver’s memory 

(reset to default settings).

9.  Basic ROP-21 parameters are configured by means of a mobile application. 

10. A remote software update of a receiver is also possible due to a mobile application (the EXTA 

LIFE controller must be connected to the Internet).

DEFAULT SETTINGS 

Parameter

Default settings

Configuration 

possibilities

output mode after power supply 

has been applied

• Switched off (open contacts 11-14) • yes – mobile application

Input types: IN1, IN2 

• cooperation with monostable 

(push-buttons) switches 

• yes – mobile application

IN1, IN2 input operation mode • bistable

• yes – mobile application

default time for output*

• 10 s

• yes – mobile application

• PROG push-button

*refers to push-buttons assigned to a receiver in time mode

CONNECTION

APPEARANCE

Input terminals

Output terminals

Power supply terminals

Signalling diode - RGB

(receiving / transmission / mode)

Programming push-button

Summary of Contents for ROP-21

Page 1: ...n switching off time Number of external inputs 2 Cooperation with push buttons monostable push buttons bistable Operating modes for external inputs only switching on only switching off bistable monost...

Page 2: ...lity The receiver has an implemented function of a re mote software update by means of the controller FUNCTIONALITY 1 The ROP 21 receiver can be simultaneously controlled by EXTA LIFE system transmitt...

Page 3: ...ied the receiver will carry out service activities for about 5 seconds it is signalled by a green STATUS LED it will flash at an interval of 1 second During this time the control of a receiver is not...

Page 4: ...ATUS LED flashes orange to signal the push buttons have been assigned correctly Bistable mode 1 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 2 In 5 sec press the b...

Page 5: ...mitter should cooperate with a receiver In case of ROP 21 the switch on switch off bistable monostable and time modes are possible 6 Choose push buttons of a transmitter that will be assigned remotely...

Page 6: ...y transmitter s push buttons from a receiver it is required that the receiver is paired with the EXTA LIFE controller To do the above the following steps must be carried out 1 Choose the Configure opt...

Page 7: ...con is assigned to the ROP 21 receiver 7 The receivers just after pairing can be controlled at once by means of application buttons The receiver s mode is signalled by a switch position and a switch i...

Page 8: ...guration change 1 Activate the application and enter the Device screen 2 Select the Configure option from the receiver s menu 3 Expand the screen and configure separately the IN1 and IN 2 input First...

Page 9: ...ed only by an authorised user an administra tor It is required to connect the EXTA LIFE controller to the Internet to carry out the update The current ROP 21 software update is displayed in the Config...

Reviews: