background image

4. Next, define for each input the ‘Input mode’. The operation modes depend on the previously 

selected ‘Input type’.

Monostable switch modes

Bistable switch modes

bistable

bistable

time

time

monostable

-

switch on

switch on

switch off

switch off

5. In case of time mode selection, it is required to additionally define the switching on time param-

eter of the receiver’s input by means of wired inputs.

Time is defined in the range from 1 sec. to 18 hrs. in the following form: hours: minutes: seconds.

CAUTION: The switching on time is assigned to an input. There is not a possibility that 

a receiver’s output is switched on with time t1 by means of IN1 input and with time t2 by 

means of IN2 input.

6. Press the ‘Save’ button to save all settings – the settings will be saved in the receiver.

Remarks:

•  IN1 and IN2 inputs are independently configured – for example, the IN 1 input can cooperate 

with a monostable switch in a bistable mode and the IN2 input with a bistable switch in time 

mode.

•  If one input should realise the receiver’s switch on function and the other one the switch off 

function, then the switch on function must be assigned to the IN1 input and the switch off func-

tion to the IN2 input (or inversely).

•  In case of monostable switches, the outputs react only to short impulses (rising edge). An 

exception includes the monostable mode with an input switched on as long as the push-button 

connected to a receiver’s input is pressed.

•  In case of bistable switches, inputs react only to the rising and falling edge. It means, if a switch 

position is changed it triggers a particular mode.

•  The structure of outputs is designed to a long term trigger, which is very important during switch 

application. 

INPUT FUNCTIONALITY

•  The IN1 and IN2 inputs are used in a wired control of the ROP-21 receiver’s output. They 

are fully configured by means of the EXTA LIFE mobile application. The configuration means 

choosing this type of switch that is connected to a particular input, operation mode and time 

value in case of selecting time mode

•  Default settings – refer to both inputs (IN1 and IN2):

  Switch type: monostable (1 push-button)

  Operation mode: bistable.

•  IN1 and IN2 inputs control the receiver’s input independently. 

Input configuration change:

1. Activate the application and enter the Device screen.

2. Select the ‘Configure’ option from the receiver’s menu.

3. Expand the screen and configure separately the IN1 and IN 2 input. First, select the switch type 

connected to the IN1 and IN 2 inputs. Define the ‘IN1 input type’ for input 1.  Define the ‘IN2 

input type’ for input 2. There are two types of switches to choose:

•  monostable (push-button) switch,

•  bistable (push-button) switch,

SWITCHING ON / SWITCHING OFF PAIRING (BROADCAST OFF)

Switching off pairing (broadcast) is recommended, if a receiver operates in the EXTA LIFE system 

without a controller (e.g. only with radio transmitters). Switching off pairing causes a receiver is 

not visible in the search process carried out by means of a controller. The above protects against 

taking over control of a receiver by unauthorised users. This situation does not take place in case a 

receiver has been previously paired with a controller. In such a case, it is not visible for other control-

lers in the search process of receivers. Summarising, in order to protect correctly your system, the 

following must be carried out:

1. If there is no controller in the EXTA LIFE system – switch off pairing (Broadcast OFF) in all receiv-

ers.

2. If there is a controller in the EXTA LIFE system – pair each receiver with the controller..

Switching off pairing is a reversible process. It means, if the EXTA LIFE controller is installed in 

the system, pairing function must be switched on, so that receivers can be found in this system.

SWITCHING OFF PAIRING (BROADCAST OFF)

In order to switch off pairing the following must be carried out:

1. Disconnect power supply from the receiver.

2. Press the PROG. push-button on a receiver.

3. While the PROG. push-button is pressed, switch on power supply.

4. Keep the PROG. push-button pressed for about 5 seconds.

5. Gdy dioda STATUS kilkukrotnie zamruga na pomarańczowo należy zwolnić PROG push-button.

6. After the above steps were carried out, pairing is switched off.

SWITCHING ON PAIRING (BROADCAST ON)

In order to activate pairing, it is necessary to reset the receiver to default settings (see Deleting the 

whole memory of a receiver).

CAUTION: As a result of the above, all data (push-buttons, times) entered to a receiver’s 

memory are deleted. They must be added again. The easiest way to do it is by means of the 

exta life mobile application, and just after the exta life controller has been installed.

Summary of Contents for ROP-21

Page 1: ...n switching off time Number of external inputs 2 Cooperation with push buttons monostable push buttons bistable Operating modes for external inputs only switching on only switching off bistable monost...

Page 2: ...lity The receiver has an implemented function of a re mote software update by means of the controller FUNCTIONALITY 1 The ROP 21 receiver can be simultaneously controlled by EXTA LIFE system transmitt...

Page 3: ...ied the receiver will carry out service activities for about 5 seconds it is signalled by a green STATUS LED it will flash at an interval of 1 second During this time the control of a receiver is not...

Page 4: ...ATUS LED flashes orange to signal the push buttons have been assigned correctly Bistable mode 1 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 2 In 5 sec press the b...

Page 5: ...mitter should cooperate with a receiver In case of ROP 21 the switch on switch off bistable monostable and time modes are possible 6 Choose push buttons of a transmitter that will be assigned remotely...

Page 6: ...y transmitter s push buttons from a receiver it is required that the receiver is paired with the EXTA LIFE controller To do the above the following steps must be carried out 1 Choose the Configure opt...

Page 7: ...con is assigned to the ROP 21 receiver 7 The receivers just after pairing can be controlled at once by means of application buttons The receiver s mode is signalled by a switch position and a switch i...

Page 8: ...guration change 1 Activate the application and enter the Device screen 2 Select the Configure option from the receiver s menu 3 Expand the screen and configure separately the IN1 and IN 2 input First...

Page 9: ...ed only by an authorised user an administra tor It is required to connect the EXTA LIFE controller to the Internet to carry out the update The current ROP 21 software update is displayed in the Config...