background image

CONFIGURATION OF INPUTS

CONFIGURATION OF OUTPUTS

SWITCHED ON

The relay is switched on after a defined input status was detected.

SWITCHED OFF

The relay is switched off after a defined input status was detected.

TIME

The relay status is switched on for a specific time after a defined input status was detected.

TIME ADJUSTMENTFOR “TIME” OPTION

SWITCHED ON

After power supply voltage is applied or switched off and then again after power supply voltage is applied, the output 

remains in the switched on status.

SWITCHED OFF

After power supply voltage is applied or switched off and then again after power supply voltage is applied, the output 

remains in the switched off status.

PREVIOUS

After power supply voltage is applied or switched off and then again after power supply voltage is applied, the output has 

the status remembered before power supply voltage was switched off (the parameter is not adjusted for the time mode).

CONFIGURATION OF OUTPUTS IN TIME MODE

TEXT MESSAGE OPTION

Solution 1:  after a recorded input occurrence: input acti a text message with a defined contentis sent (the text message is 

sent to all authorised telephone numbers included in the INFO).

Solution 2:  after a recorded input occurrence only a text message with a defined contentis sent (the text message is sent to all au-

thorised telephone numbers included in the INFO).

CONFIGURATION OF OUTPUTS IN GATE MODE

It defines the occurrence that needs to 

be activated in case a defined status 

occurs on an input.

The logical 

IN1/IN2 inputs 

status.

A possibility of CLIP control

switching on / switching off.

Number of signals to control CLIP.

Adjustments from 2 to 12.

Defines time change of the status for channel 2.

Adjustments in the range from 0 to 3600 sec.

Defines the gate electric latch switch on time.

Adjustments in the range from 0 to 60 sec.

Number of signals during CLIP control. 

Adjustments in the range from 2 to 6 sec.

Time for automatic mode. 

Adjustments in the range from 1 to 600 sec.

Automatic mode selection.

Defines time change of the status for channel 1.

Adjusted in the rangefrom 0 to 3600 sec.

Defines the pulse duration time to the gate controller. 

Adjustments in the range from 0 to 10 sec.

Operating mode selection.

An independent mode for each output.

A default output status after power supply

is switched on / switched off.

If the option “Relay 1’ was chosen or 

“Relay 2” the user has the following 

options:

The text message content (maximum 32 signs).

Time adjustment for the time mode.

Adjustments in the range 0...3600 sec.

Afterthe “LO” status is detected on the IN2 input, the relay 1 (OUT1) status is changed for time 10 sec. + a text message

“OUT1 TIME CHANGE” is sent to all authorised telephone numbers defined in the INFO.

After the “LO status is detected on the IN2 input, a text message including “IN2 LOW STATUS”

content is sent to all authorised telephone numbers defined in the INFO.

Reviews: