background image

TWILIGHT SWITCH WZH - 01

 

INSTRUCTION MANUAL

APPEARANCE

FEATURES

TECHNICAL PARAMETERS

DESCRIPTION

ver. 0.4.1 _ 2006.06.27_14:00

WZH - 01

Power supply cables: L (black), N (blue)

Input rated voltage: 230 V~

Input voltage tolerance: from -15 to +10 %

Nominal frequency: 50 / 60 Hz

Rated power consumption: 24 mA

Output (load) cables: L (brown) , N (grey)

Threshold adjustment range: from 0 to 200 lx (potentiometer)

Lighting sensor: inner

Output relay parameters: 1NO-16 A / 250 V AC1 4000 VA (voltage contact)

Number of switch cables: 4

Section of connecting cables: 4x 1,50 mm

Length of connecting cables: 0,5 m

Ambient temperature range: from -20 to +45 

o

C

Operating position: vertically, cable down

Mounting: 2x stretcher 5x(3x30)

Protection level of casing: IP65 (EN 60529)

Protective class: II

Overvoltage category: II

Pollution degree: 2

Rated impulse withstand voltage: 1 kV (EN 61000-4-5)

Dimensions: 69x56x27 mm

Weight: 104 g

Reference standards: EN 60669-1

EN 60669-2-1

EN 61000-4-2,3,4,5,6,11

ی  It allows to switch on and/or switch off 

lighting devices according to the pre-

set ambient light level,

ی  adjustment of the switch on threshold,
ی  wide  setting  scope  of  the  switch  on 

threshold (from 0 to 200 lx),

ی  inner lighting sensor,
ی  resistant to momentary changes of lu

-

minous flux density,

ی  hysteresis  of  the  switch-over  thres

-

hold,

ی  hermetic (IP65 protection degree) en

-

closure,

ی  voltage relay output max 16 A capaci

-

ty.

The  twilight  switch  WZH-01  is  used 

to  control  lighting  devices  and  other 

energy  receivers  depending  on  luminous 

flux density. The system switches on the 

lighting at dusk and switches off at dawn. 

The  switching  on  threshold  can  be  adju-

sted by the user. The system is resistant 

to  momentary  changes  of  luminous  flux 

density and the same guarantees its relia-

bility. The hermetic casing (IP65) secures 

the device functioning in unfavorable we-

ather conditions.

Zakład Mechaniki i Elektroniki 

ZAMEL 

sp.j.

J.W. Dzida, K. Łodzińska

Zielona 27, 43-200 Pszczyna, Poland

Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04

www.zamel.pl, 

e-mail:

 [email protected]

The device is designed 

for  one-phase  installa-

tion and must be instal-

led  in  accordance  with 

standards valid in a par-

ticular country. The devi-

ce should be connected 

according  to  the  details  included  in  this 

operating manual. Installation, connection 

and control should be carried out by a qua-

lified electrician staff, who act in accordan

-

ce with the service manual and the device 

functions. Disassembling of the device is 

equal  with  a  loss  of  guarantee  and  can 

cause  electric  shock.  Before  installation 

make sure the connection cables are not 

under voltage. The cruciform head screw-

driver  3,5  mm  should  be  used  to  instal 

the  device.  Improper  transport,  storage, 

and use of the device influence its wrong 

functioning. It is not advisable to instal the 

device in the following cases: if any device 

part is missing or the device is damaged or 

deformed. In case of improper functioning 

of the device contact the producer.

CAUTION

bl

a

c

k

b

l

ue

grey

br

ow

n

Power supply cable (L)
Power supply cable (N)

Output (load) cable (N)
Output (load) cable (L)

Inner lighting sensor

Adjustment of the switch on threshold

Reviews: