4.2 Temperature and Humidity Test
Test Item
Specification
Test Equipment
High Temp
High Humidity
Test
1. Test Condition: 50°C /95%, 120 hours
2. Judgment Standard:
i) No malfunction
ii) No decay inside of the product
Chamber
Storing in Low
Temperature
1. Test Condition: -20°C, 96 hours
2. Judgment Standard:
- No malfunction
Chamber
4.3 Heat Treatment Impact Test
Test Item
Specification
Test Equipment
Heat Treatment
Impact Test
1. Test Condition: -40°C ~ 85°C, 2 hours
/cycle, 30cycle
2. Judgment Standard:
i) No malfunction
ii) No decay or color change of PBA Soldering
& component
iii) No crack, dent, or change
Chamber
4.4 Vibration Test
Test Item
Specification
Test Equipment