14 Operation and Maintenance Manual
MQ-150 Ballscrew Feed Unit
Power up Screen
Verify that control power is on and follow menus instructions on screen.
(F2)
– Allows program to process through error routines internal to motion
controller.
Security Screen
The security screen is provided to keep unauthorized personal from changing
setup data.
Security code –
The security code is set to 1958 on all models unless otherwise specified
by customer. The code can be changed if necessary by uploading the current program
(see programming section) and changing the password.
Menu functions
Each of the menu functions is described below.
Main Menu -
Menu displayed after power-up sequence
Setup (F1) -
Goes to SETUP MENU #1
Pulleys (F1) -
Goes to pulley settings display menu
NEXT (F3) -
Allows current pulley settings to be changed
Enter driver pulley # of teeth -
operator entry
Enter driven pulley # of teeth -
operator entry
EXIT (F6) -
Exits to SETUP MENU #1 without changing settings
Select (F5) –
Goes to TOOL SELECT for selecting keypad input or digital
inputs.
Home (F2) -
Actuates homing sequence of unit
NEXT (F3) -
Goes to SETUP MENU #2
Enter tool number -
operator entry
Jog (F2) -
allows unit to be jogged in and out using arrow keys
Fast (F1) -
Selects fast jog, good for approaching part
Slow (F2) -
Selects slow jog, good for near part motion
Exit (F6) -
Exits back to SETUP MENU #2
Pos? (F3) -
Displays current position
Arrayinit (F4) -
Allows tool data storage array to be reset
. Note
once security code has been entered all tool data will be erased.
Exit (F6) -
Exits back to SETUP MENU #1
Tool (F4) -
Allows tool/part/cycle to be set up
Enter tool number -
Allows entry of tool number to be set up
Select tool type -
Select tool type from list (Ex. drill, tap, etc.)
Back (F1) -
Move back one tool in list
Next (F2) -
Move forward one tool in list