ZCube-SC User Guide
DOC-USR-0265-01
______________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
67
Bottom Left
Bottom Center
Bottom Right
Overlay Text Size
16 px
32 px
64 px
Sets size of display text in pixels.
Channel Controls
Stop Button
Stop current encode session for Channel 1.
Encode must be stopped in order for settings
to be altered.
Start Button
Start encode session for Channel 1.
Delete Button
Removes channel instance for encoding.
status
!Not running,
IDLE, STOPPED,
RUNNING,
POLLING
Current status of the encode process.
IDLE
indicates no valid input data is present.
STOPPED
indicates that the unit is not
currently encoding. Must be in this mode to
make any configuration changes.
POLLING
indicates “start” was pressed and
the encoder is waiting for valid input data to
be detected.
RUNNING
indicates the unit is currently
encoding.
Error statuses will be preceded by an
exclamation point and include a description
of the error.
Note 1: Encode Resolutions Supported: