10
RabbitCore RCM3600
2.2.3 Connect Power
When all other connections have been made, connect the wall transformer to 3-pin header
J4 on the Prototyping Board as shown in Figure 3. The connector may be attached either
way as long as it is not offset to one side.
Plug in the wall transformer. The LED above the
RESET
button on the Prototyping Board
should light up. The RCM3600 and the Prototyping Board are now ready to be used.
NOTE:
A
RESET
button is provided on the Prototyping Board to allow a hardware reset
without disconnecting power.
2.2.3.1 Overseas Development Kits
Development kits sold outside North America include a header connector that may be
connected to 3-pin header J4 on the Prototyping Board. The connector may be attached
either way as long as it is not offset to one side. The red and black wires from the connec-
tor can then be connected to the positive and negative connections on your power supply.
The power supply should deliver 7.5 V–30 V DC at 500 mA.