User’s Manual
51
Calibrates the response of the A/D converter channel as a linear function using the two conversion points
provided. Four values are calculated and placed into global table
_adcCalib
to be stored later into
using the function
anaInEEWr()
. Each channel will have the following information:
a linear constant,
a voltage offset,
a calculation gain code used to calculate calibrations, and
a user gain code to set voltage range (defaults to the calculation gain code).
PARAMETERS
channel
is the analog input channel number (0 to 7) corresponding to AIN0–AIN7
opmode
is the mode of operation:
SINGLE
—single-ended input line
DIFF
—differential input line
gaincode
is the gain code of 0 to 7:
int anaInCalib(int channel, int opmode,
int gaincode, int value1, float volts1,
int value2, float volts2);
channel
SINGLE
DIFF
0
+AIN0
+AIN0 -AIN1
1
+AIN1
—
2
+AIN2
+AIN2 -AIN3
3
+AIN3
—
4
+AIN4
+AIN4 -AIN5
5
+AIN5
—
6
+AIN6
+AIN6 -AIN7
7
+AIN7
—
Gain Code
Multiplier
Voltage
Range
0
×1
0–20 V
1
×2
0–10 V
2
×4
0–5 V
3
×5
0–4 V
4
×8
0–2.5 V
5
×10
0–2 V
6
×16
0–1.25 V
7
×20
0–1 V
Summary of Contents for eDisplay OP7200
Page 1: ...eDisplay OP7200 VGA Operator Control Panel User s Manual 019 0116 021001 A ...
Page 6: ...eDisplay OP7200 ...
Page 44: ...38 eDisplay OP7200 ...
Page 128: ...122 eDisplay OP7200 ...
Page 136: ...130 eDisplay OP7200 ...
Page 144: ...138 eDisplay OP7200 ...
Page 146: ...140 eDisplay OP7200 ...
Page 150: ...144 eDisplay OP7200 ...
Page 152: ......