Basic (version 1)

Binary Switch (version 1)

Multilevel Switch (version 3)

Version (version 1)

Indicator (version 1)

All Switch (version 1)

Multi Channel Association (version 2)

Con guration (version 1)

Manufacturer Speci c (version 1)

Protection (version 1)

Node Naming and Location (version 1)

Association (version 2)

Multi Channel (version 2)

Scene Activation (version 1)

Scene Actuator Con guration (version 1)

Scene Controller Con guration (version 1)

Controlled Command Classes

Basic (version 1)

Multilevel Switch (version 3)

All Switch (version 1)

Multi Channel (version 2)

Scene Activation (version 1)

Technical Data

Power Supply

230V ~50-60 Hz

Attachable Loads

Motors up to 1800 W

Fuse

Type: T 1.25 A H (Load 1.25 Ampere, high shutdown capacity), D: 5 mm, L: 20 mm

IP Rating

IP 20

Frequency

868.42 MHz (SRD Band)

Wireless Range

up to 100 m outside, on average up to 20 m inside buildings

Explorer Frame Support Yes

SDK

4.54.01

Device Type

Slave with routing capabilities

Generic Device Class

Multilevel Switch

Speci c Device Class

Motor Control Class C

Routing

Yes

FLiRS

No

Firmware Version

1.8

Explanation of Z-Wave speci c terms

Summary of Contents for ZME_05459

Page 1: ...er actuators There are two different role a controller can have There is always one single primary controller that is managing the network and including excluding devices The controller may have other functions like control buttons as well All other controllers don t manage the network itself but can control other devices They are called secondary controllers The image also shows that its not poss...

Page 2: ...ed to be connected to the cable to the load The cable from the load is connected to neutral N If there are both neutral and hot wire in the wall box the neutral from the mains panel and the neutral to the lamp need to be connected It is not harmful if the two connections L and S are mismatched on the actuator A fuse protects the electronics of the actuator The fuse is accessible on the top side of...

Page 3: ...te operation functions to the double click of the paddles Child Protection The device can be turn into a child protection mode In this mode all local operation is disabled The child protection mode MUST be turned on wirelessly However in protected by sequence mode it is possible to unlock the device for local operation with a triple click The unlock state will last for 5 seconds LED Control Red an...

Page 4: ...Default 1 Ignore 2 Open 3 Open if closed else close Full close time Parameter Number 4 Parameter Size 1 Time to go from opened to closed state Used to estimate the current level Note that in Permanent motion mode the reported value would a be Closed or Opened while all Basic and Multilevel Set values 1 99 255 would Open except 0 value that would Close Value Description 0 Keep in permanent motion 1...

Page 5: ... and close relays if blind control is wired to the motor incorrectly Value Description 0 No Default 1 Yes Typical click timeout Parameter Number 10 Parameter Size 1 Typical time used to differentiate click hold double and triple clicks Value Description 1 100 in 10ms units Default 50 Invert buttons Parameter Number 11 Parameter Size 1 Value Description 0 No Default 1 Yes Switch by buttons Paramete...

Page 6: ...ck timeout to see if the second click would be pressed This will introduce a small delay for single click commands Value Description 0 Disabled Default 4 Switch On Off and Dim send Basic Set and Switch Multilevel 1 Switch On Off only send Basic Set 2 Switch All 3 Send Scenes 5 Send Precon gured Scenes Send the following Switch All commands Parameter Number 15 Parameter Size 1 Value Description 1 S...

Page 7: ...d Classes Basic version 1 Multilevel Switch version 3 All Switch version 1 Multi Channel version 2 Scene Activation version 1 Technical Data Power Supply 230V 50 60 Hz Attachable Loads Motors up to 1800 W Fuse Type T 1 25 A H Load 1 25 Ampere high shutdown capacity D 5 mm L 20 mm IP Rating IP 20 Frequency 868 42 MHz SRD Band Wireless Range up to 100 m outside on average up to 20 m inside buildings...

Page 8: ...sociation is a control relationship between a controlling device and a controlled device Wakeup Noti cation is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product does not contain hazardous chemicals Do...

Reviews: